Results 81 to 90 of about 7,559,493 (146)
Optimizing the sensitivity and speed of the overcurrent protection system in the presence of distributed generation units while also ensuring the cost-effective design of the fault current limiter (FCL) represents great challenges for engineers.
Mahmoud A. Elsadd +4 more
doaj +1 more source
Design and application of superconducting fault current limiter in a multiterminal HVDC system [PDF]
Voltage source converter based HVdc (VSC-HVdc) systems are prone to high short-circuit current during transmission line faults. The situation for multiterminal HVdc (MTDC) systems is worse.
Yuan, Weijia +5 more
core +2 more sources
The production of bulk Bi2+xSr3-yCa yCu 2O8+delta (Bi-2212) superconductors for fault current limiter application was developed via a partial-melting route.
Bojan A. Marinkovic +6 more
doaj +1 more source
Design of a multifunction novel flexible fault current limiter for AC distribution network. [PDF]
Liu Y +7 more
europepmc +1 more source
Abstract In order to enhance the stability and reliability of the Photovoltaic-Energy storage-Direct-Flexible (PEDF) system, a novel line-compensation superconducting magnetic energy storage-fault current limiter (SMES-FCL) was designed to address voltage fluctuations and fault current limiting issues.
Baohua Liu +4 more
openaire +1 more source
Valve-side single-phase-to-ground (SPG) faults are atypical yet critical for the operation of half-bridge (HB) Modular Multilevel converter (MMC) bipolar or asymmetrical monopolar systems.
Muhammad Usman +2 more
doaj +1 more source
With the continuous development of power grid, the high short-circuit threatens the stability of the power system. The short-circuit exceeds the disconnection capacity of the circuit breaker and has a negative impact on the integrity and stability of the
Duanjiao Li +9 more
doaj +1 more source
Analysis and mitigation of PQ disturbances in grid connected system using fuzzy logic based IUPQC. [PDF]
Ravi T +4 more
europepmc +1 more source
Simulation of fault current limiter in reducing fault current
TK3226.F35 2020Increasing electricity power demand leads to increasing electrical loads in power system network. A significant rise in fault current may introduced to power systems that have been stretched to their designed capacity. Fault current levels
Muhammad Faizal Bin Baili
core
Air force distribution feeder, or R1-G4, in Bahir Dar substation is affected by total harmonic distortion from nonlinear loads, voltage sag from short-circuit faults that occurred on the system, and voltage swell.
Yechale Amogne +2 more
doaj +1 more source

