Results 21 to 30 of about 8,770,058 (155)
Topology and control strategy of a multifunctional modular DC fault current limiter
DC fault current limiter (FCL) is a key device for suppressing DC short-circuit fault currents,which is important in AC/DC hybrid grid. In this paper,topology of a multifunctional modular DC FCL is proposed,which consists of multiple series-connected ...
ZHANG Liang +4 more
doaj +1 more source
The modular multilevel converter (MMC) topology is very suitable for high voltage direct current (HVDC) system to achieve feasible power control, favorable black start capability as well as long-distance power transmission.
Lei Chen +4 more
doaj +1 more source
Operational control and protection implications of fault current limitation in distribution networks [PDF]
Rising short-circuit fault current levels is one of the problems associated with the increased presence of distributed generation (DG) in electrical networks.
Blair, S.M. +3 more
core +3 more sources
This paper presents a new bridge Fault Current Limiter (FCL) used for the improvement of the transient stability of steam turbine-based power plants.
Dmitry Baimel
doaj +1 more source
The wind energy conversion technology of a Permanent Magnet Synchronous Generator (PMSG) is very promising in renewable power generation. However, the performance of the grid-connected PMSGs is greatly affected by grid disturbances because their stator ...
Kenneth E. Okedu, Kenneth E. Okedu
doaj +1 more source
The low voltage direct current (LVDC) distribution networks are connected with too many kinds of loads and sources, which makes them prone to failure.
Bing Han, Yonggang Li
doaj +1 more source
Implications of fault current limitation for electrical distribution networks [PDF]
This paper explores the potential future need for fault current limitation in the UK's power system, and some of the technical implications of this change.
Blair, S.M. +11 more
core +3 more sources
The use of fault current limiter to reduce the operating time of relays [PDF]
In distribution network with displacement at network level, the fault current does not significantly change and it is not possible to effectively utilize the inverse time over-current relays, since, if the number of primary and backup relays increases ...
Ehsan Khoob +2 more
doaj +1 more source
Design and Analysis of Fault Current Limiter Based on Air Core Variable Series Reactor
With the ongoing growth of the interconnected electric power systems and the increase of the short circuit current level in the power network, electric power equipment that are capable of limiting the fault current are gaining interest.
Moslem Amini +2 more
doaj +1 more source
A contribution to the engineering application of a proposed 500 kV fault current limiter (FCL) is presented. A new type of FCL composed of a highly coupled split reactor (HCSR) and fast switches is proposed.
Qiang Tang +6 more
doaj +1 more source