Results 71 to 80 of about 150 (127)

Optimum Coordination Approach for Directional Overcurrent Relays in Interconnected Power Systems Considering Uncertainty in Photovoltaic Generation

open access: yesIEEE Access
Optimizing the sensitivity and speed of the overcurrent protection system in the presence of distributed generation units while also ensuring the cost-effective design of the fault current limiter (FCL) represents great challenges for engineers.
Mahmoud A. Elsadd   +4 more
doaj   +1 more source

Development of Bulk Bi2+xSr3-yCa yCu 2O8+delta Superconductors by Partial-Melting Route for Fault Current Limiters Application

open access: yesMaterials Research, 2002
The production of bulk Bi2+xSr3-yCa yCu 2O8+delta (Bi-2212) superconductors for fault current limiter application was developed via a partial-melting route.
Bojan A. Marinkovic   +6 more
doaj   +1 more source

Enhancing stability of Photovoltaic-Energy storage-Direct current-Flexibility power system with a novel integrated Superconducting Magnetic Energy Storage-Fault Current Limiter (SMES-FCL)

open access: yesJournal of Physics: Conference Series
Abstract In order to enhance the stability and reliability of the Photovoltaic-Energy storage-Direct-Flexible (PEDF) system, a novel line-compensation superconducting magnetic energy storage-fault current limiter (SMES-FCL) was designed to address voltage fluctuations and fault current limiting issues.
Baohua Liu   +4 more
openaire   +1 more source

Fault Current Limiter and Mechanical DC CB-Based Protection Against Valve-Side SPG Faults in HB-MMC Bipolar System

open access: yesIEEE Access
Valve-side single-phase-to-ground (SPG) faults are atypical yet critical for the operation of half-bridge (HB) Modular Multilevel converter (MMC) bipolar or asymmetrical monopolar systems.
Muhammad Usman   +2 more
doaj   +1 more source

Influence of Shunt Branch on the Current Limiting and Recovery Performance of Variable Resistance SFCL

open access: yesIEEE Access
With the continuous development of power grid, the high short-circuit threatens the stability of the power system. The short-circuit exceeds the disconnection capacity of the circuit breaker and has a negative impact on the integrity and stability of the
Duanjiao Li   +9 more
doaj   +1 more source

Fault current limiting dynamic voltage restorer for power quality improvement in distribution system (case study: air force feeder)

open access: yesJournal of Electrical Systems and Information Technology
Air force distribution feeder, or R1-G4, in Bahir Dar substation is affected by total harmonic distortion from nonlinear loads, voltage sag from short-circuit faults that occurred on the system, and voltage swell.
Yechale Amogne   +2 more
doaj   +1 more source

Optimal Multiple FCLs Allocation Considering DG Penetration in Meshed Network With Multi-Level Voltages

open access: yesIranian Journal of Electrical and Electronic Engineering, 2020
Increasing the short circuit current due to the penetration of distributed generations (DGs) in various voltage levels and meshed topology is a basic problem in power systems.
M. Hosseinpour, J. Sadeh
doaj  