Analysis and mitigation of PQ disturbances in grid connected system using fuzzy logic based IUPQC. [PDF]
Ravi T +4 more
europepmc +1 more source
Design and application of superconducting fault current limiter in a multiterminal HVDC system [PDF]
Voltage source converter based HVdc (VSC-HVdc) systems are prone to high short-circuit current during transmission line faults. The situation for multiterminal HVdc (MTDC) systems is worse.
Yuan, Weijia +5 more
core +1 more source
Essential Material Knowledge and Recent Model Developments for REBCO-Coated Conductors in Electric Power Systems. [PDF]
Trillaud F +2 more
europepmc +1 more source
Air force distribution feeder, or R1-G4, in Bahir Dar substation is affected by total harmonic distortion from nonlinear loads, voltage sag from short-circuit faults that occurred on the system, and voltage swell.
Yechale Amogne +2 more
doaj +1 more source
Increasing the short circuit current due to the penetration of distributed generations (DGs) in various voltage levels and meshed topology is a basic problem in power systems.
M. Hosseinpour, J. Sadeh
doaj
A Remaining Useful Life Prognosis of Turbofan Engine Using Temporal and Spatial Feature Fusion. [PDF]
Peng C +5 more
europepmc +1 more source
Design of a 10kV,500A Inductive Superconducting Fault Current Limiter
The design aspect of a 10kV,500A inductive superconducting fault current limiter was analyzed. The effect of the superconductor in the fault current limiter was defined. When placed in the system, in the absence of fault current,the superconducting fault
Akejelu, Daniel Limi
core
Reliable fault current limitation is critical in high-voltage direct current (HVDC) grids due to the fast dynamics and low fault tolerance of power electronic equipment, as well as the high cost of DC circuit breakers (DCCBs). To address these challenges,
Yuhong Wang +5 more
doaj +1 more source
The impact of fault current limiter in power system performance [PDF]
Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers ...
Mohd. Ariff, Mohd. Aifaa +1 more
core +2 more sources
Using non-superconducting fault current limiter as inrush current limiter
In this paper, inrush current limitation of transformer using a bridge type fault current limiter (FCL) as inrush current limiter is proposed.
Seyedbehzad Naderi (14745067) +2 more
core +1 more source