Results 91 to 100 of about 6,133,186 (147)

Design and application of superconducting fault current limiter in a multiterminal HVDC system [PDF]

open access: yes, 2017
Voltage source converter based HVdc (VSC-HVdc) systems are prone to high short-circuit current during transmission line faults. The situation for multiterminal HVdc (MTDC) systems is worse.
Yuan, Weijia   +5 more
core   +1 more source

Fault current limiting dynamic voltage restorer for power quality improvement in distribution system (case study: air force feeder)

open access: yesJournal of Electrical Systems and Information Technology
Air force distribution feeder, or R1-G4, in Bahir Dar substation is affected by total harmonic distortion from nonlinear loads, voltage sag from short-circuit faults that occurred on the system, and voltage swell.
Yechale Amogne   +2 more
doaj   +1 more source

Optimal Multiple FCLs Allocation Considering DG Penetration in Meshed Network With Multi-Level Voltages

open access: yesIranian Journal of Electrical and Electronic Engineering, 2020
Increasing the short circuit current due to the penetration of distributed generations (DGs) in various voltage levels and meshed topology is a basic problem in power systems.
M. Hosseinpour, J. Sadeh
doaj  

Design of a 10kV,500A Inductive Superconducting Fault Current Limiter

open access: yes, 2017
The design aspect of a 10kV,500A inductive superconducting fault current limiter was analyzed. The effect of the superconductor in the fault current limiter was defined. When placed in the system, in the absence of fault current,the superconducting fault
Akejelu, Daniel Limi
core  

Coordinated Source-Grid fault current limiting strategy in HVDC grids based on fault severity and quantitative limitation demand

open access: yesInternational Journal of Electrical Power & Energy Systems
Reliable fault current limitation is critical in high-voltage direct current (HVDC) grids due to the fast dynamics and low fault tolerance of power electronic equipment, as well as the high cost of DC circuit breakers (DCCBs). To address these challenges,
Yuhong Wang   +5 more
doaj   +1 more source

The impact of fault current limiter in power system performance [PDF]

open access: yes, 2009
Continues growth of electrical energy demand is resulting in a corresponding increase in the short circuit in power system. Several solutions have been implemented, including the use of Fault Current Limiter (FCL), in order to reduce circuit breakers ...
Mohd. Ariff, Mohd. Aifaa   +1 more
core   +2 more sources

Using non-superconducting fault current limiter as inrush current limiter

open access: yes, 2011
In this paper, inrush current limitation of transformer using a bridge type fault current limiter (FCL) as inrush current limiter is proposed.
Seyedbehzad Naderi (14745067)   +2 more
core   +1 more source