Results 81 to 90 of about 1,378 (185)

Multi-Objective Optimal Placement of Fault Current Limiter in IEEE RTS 24-Bus System: A Case Study Review

open access: yes, 2023
By increasing load demands and extending power networks to respond to customers’ needs, the complexity and integration of power systems have been boosted, increasing the system’s short circuit current level, which may threaten the network’s reliability ...
Ali Mahmoudian, Mahmoudian, Ali
core   +1 more source

A Dynamic Multi-Cell FCL to Improve the Fault Ride through Capability of DFIG-Based Wind Farms

open access: yesEnergies, 2020
Endowing wind farms (WFs) with fault ride through (FRT) capability is crucial to their continuous availability under various operating conditions. This paper proposes a dynamic adaptive multi-cell fault current limiter (MCFCL) topology to enhance the FRT
M. R. Shafiee   +4 more
doaj   +1 more source

Evaluation of a Therapeutic Drug Monitoring Strategy for Adalimumab in Psoriasis: A Prospective Pharmacokinetic‐Pharmacodynamic Study

open access: yesClinical and Translational Science, Volume 19, Issue 5, May 2026.
ABSTRACT Using a real‐world psoriasis cohort, we established the pharmacokinetic‐pharmacodynamic (PKPD) relationship for the biologic therapy adalimumab and evaluated the clinical utility and cost‐effectiveness of a proactive therapeutic drug monitoring (TDM) strategy.
Shan Pan   +38 more
wiley   +1 more source

Fundamental performance of flux-lock type fault current limiter with two air-core coils [PDF]

open access: yes, 2003
This paper proposes a superconducting fault current limiter (FCL) which is a modified version of the flux-lock type fault current limiter developed by us. This FCL consists of a high Tc superconductor (HTS) and two coaxial air-core coils.
Goto, M.   +4 more
core   +1 more source

Using non-superconducting fault current limiter as inrush current limiter

open access: yes, 2011
In this paper, inrush current limitation of transformer using a bridge type fault current limiter (FCL) as inrush current limiter is proposed.
Seyedbehzad Naderi (14745067)   +2 more
core   +1 more source

Fault Current Limiters for LVRT Enhancement in Wind Turbine Systems: Technologies, Trade-Offs, and Comparative Simulation Insights

open access: yesEnergies
This paper presents a comprehensive review and comparative evaluation of Fault Current Limiter (FCL) technologies for enhancing the Low-Voltage Ride-Through (LVRT) capability of Wind Turbine Generation Systems (WTGSs).
Mehdi Firouzi   +3 more
doaj   +1 more source

Bridging Superconductors With United Nations Development Goals: Perspectives and Applications

open access: yesphysica status solidi (a), Volume 223, Issue 7, 7 April 2026.
Ceramic superconductors enable sustainable technologies. A bibliometric review of 33,756 publications (1980–2025) assesses their alignment with the UN Sustainable Development Goals. Key applications identified from include clean propulsion, efficient power grids, advanced medical imaging, and quantum computing, highlighting both their transformative ...
Edimar A. S. Duran   +9 more
wiley   +1 more source

Pemodelan dan Analisis Fault Current Limiter Sebagai Pembatas Arus Hubung Singkat Pada GI Sengkaling Malang

open access: yesJurnal EECCIS (Electrics, Electronics, Communications, Controls, Informatics, Systems), 2018
Abstrak— Perkembangan penduduk dan peningkatan ekonomi masyarakat menjadi salah satu penyebab peningkatan kebutuhan energi listrik. Konsekuensinya, ketersediaan sumber dan prasarana penyaluran energi harus dapat memastikan kualitas catu daya listrik ...
Eko Kuncoro   +3 more
doaj   +1 more source

A Phase 2 Trial of Hydroxychloroquine in Individuals at Risk for Rheumatoid Arthritis

open access: yesArthritis &Rheumatology, Volume 78, Issue 4, Page 809-820, April 2026.
Objective Individuals with serum elevations of anti–cyclic citrullinated peptide (anti‐CCP) antibodies are at increased risk for future rheumatoid arthritis (RA). No pharmacologic interventions have been approved for the prevention of RA in such at‐risk individuals.
Kevin D. Deane   +33 more
wiley   +1 more source

Design and Experimental Study of a Novel Fault Current Limiter

open access: yes, 2010
Limiting the short-circuit current effectively is of great importance to keep the safe and steady running of the power system. A novel fault current limiter (FCL) on the basis of a high speed switch and a triggered vacuum switch (TVS) is presented.
Chun Zhao   +4 more
core   +1 more source

Home - About - Disclaimer - Privacy