Optimal Protection Coordination of Active Distribution Networks With Synchronverters
Synchronverters are inverters imitating synchronous generators (SGs) to curb adverse impacts of traditional inverters on power networks. However, synchronverters may generate unlimited currents during faults.
Saad Pola, Maher A. Azzouz
doaj +1 more source
Implications of fault current limitation for electrical distribution networks [PDF]
This paper explores the potential future need for fault current limitation in the UK's power system, and some of the technical implications of this change.
Blair, S.M. +5 more
core +1 more source
Since the fault dynamic of droop-controlled inverter is different from synchronous generators (SGs), protection devices may become invalid, and the fault overcurrent may damage power electronic devices and threaten the safety of the microgrid. Therefore,
Huimin Zhao +5 more
doaj +1 more source
A study on the impact characteristics of resistive-type DC fault current limiter
DC fault current limiters can rapidly restrict the rise of fault currents, but attention needs to be paid to their dynamic current-limiting characteristics during fault impact.
ZHAO Zihui +6 more
doaj +1 more source
Placement optimization of Multi-Type fault current limiters based on genetic algorithm
The fault current limiter (FCL) is an effective measure for improving system stability and suppressing short-circuit fault current. Because of space and economic costs, the optimum placement of FCLs is vital in industrial applications. In this study, two
Guofeng Jin +4 more
doaj +1 more source
The technology of variable speed wind turbines is very promising in renewable power generation. It is imperative for wind turbines to gain control after grid disturbances and contribute to the stability of power grids as part of the requirements of grid ...
Kenneth E. Okedu
doaj +1 more source
Comparison of current-limiting strategies during fault ride-through of inverters to prevent latch-up and wind-up [PDF]
Transient stability of a power network requires that generators remain synchronized and return to normal power export once a fault is cleared. For inverter-interfaced generators, one must ensure that current and voltage limiters do not latch-up and that ...
Bottrell, N, Green, TC
core +1 more source
Superconducting Fault Current Limiter.
There is disclosed a current limiter having a plurality of current limiting units provided for electric paths constituting a plurality of phases, Each current limiting unit is constituted by a superconducting coil functioning as a first current limiting element formed in a non-inductive winding manner by connecting two superconducting coils in series ...
Takeshi OHKUMA, Yoshihiro IWATA
openaire +2 more sources
Fault Current Limiters in Power Systems: A Comprehensive Review
Power systems are becoming more and more complex in nature due to the integration of several power electronic devices. Protection of such systems and augmentation of reliability as well as stability highly depend on limiting the fault currents.
Md Shafiul Alam +2 more
doaj +1 more source