Results 241 to 250 of about 869,116 (286)
Divergence Distance Based Index for Discriminating Inrush and Internal Fault Currents in Power Transformers [PDF]
This paper puts forward a new algorithm based on Kullback Leibler divergence (KLD) for discriminating inrush and internal fault currents in power transformers.
Mohsen Tajdinian, Haidar Samet
exaly +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Multicell Fault Current Limiter
IEEE Transactions on Industrial Electronics, 2014A multicell fault current limiter (MCFCL) is proposed in this paper. The MCFCL is composed of multiple fault current limiting cells. Each fault current limiting cell consists of a fault current limiting inductor and a power electronic module. The proposed MCFCL has the flexibility in expanding the operation voltage by increasing the number of fault ...
Wenyong Guo +6 more
openaire +2 more sources
Nonsuperconducting Fault Current Limiter With Controlling the Magnitudes of Fault Currents
IEEE Transactions on Power Electronics, 2009In this paper, a diode-bridge-type nonsuperconductor fault current limiter (NSFCL) is proposed. The structure has the capability of controlling the DC reactor current that yields to control the magnitude of fault current. In order to control the magnitude of DC reactor current, a discharging resistor is used in the proposed structure.
M.T. Hagh, M. Abapour
openaire +1 more source
Fault-Current Measuring Device
Transactions of the American Institute of Electrical Engineers, 1946IN electric power system operation numerous problems are encountered in analyzing the results of short circuits and in the physical location of the trouble. Some devices now available for analyzing short circuits in a-c circuits are the oscillograph, the annunciator ammeter, and a magnetic link device requiring rectifiers.
openaire +1 more source
In order to calculate fault currents in distribution systems accurately, the fault model must also include the electrical arc existing at the fault point and playing an important role in the fault currents calculation.
Rade M Ciric, V V Terzija
exaly +2 more sources
Fault Location with Current Monitoring
1991, Proceedings. International Test Conference, 2005Recently there has been renewed interest in fault detection in static CMOS circuits through current monitoring (“Iddq testing”). It is shown that accurate defect (diagnosis miay be performed with a combination of current and voltage observations. The proposed system combines a simple single fault model for test generation with a more realistic multiple
openaire +2 more sources
DC superconducting fault current limiter
Superconductor Science and Technology, 2006There is a lack of satisfying solutions for fault currents using conventional technologies, especially in DC networks, where a superconducting fault current limiter could play a very important part. DC networks bring a lot of advantages when compared to traditional AC ones, in particular within the context of the liberalization of the electric market ...
Cointe, Yannick +2 more
openaire +3 more sources
Fault-resistance effect on ground fault current
Electrical Engineering, 1953GROUND FAULT currents may be reduced substantially when fault resistance is included in the fault circuit. The majority of faults that occur on a power system involve ground and occur between conductor and tower. When a fault occurs to a steel tower or grounded wood pole on a grounded system the footing resistance is included automatically in the fault