IEEE transactions on power electronics, 2019
Voltage-controlled three-phase three-leg inverters are widely applied in various occasions. The inverters are generally switched to the current-controlled mode to limit the fault currents when short-circuit faults happen.
Xinchun Lin +4 more
semanticscholar +1 more source
Voltage-controlled three-phase three-leg inverters are widely applied in various occasions. The inverters are generally switched to the current-controlled mode to limit the fault currents when short-circuit faults happen.
Xinchun Lin +4 more
semanticscholar +1 more source
IEEE transactions on industry applications, 2019
In this paper, a practical machine learning-based fault diagnosis method is proposed for induction motors using experimental data. Various single- and multi-electrical and/or mechanical faults are applied to two identical induction motors in lab ...
M. Z. Ali +4 more
semanticscholar +1 more source
In this paper, a practical machine learning-based fault diagnosis method is proposed for induction motors using experimental data. Various single- and multi-electrical and/or mechanical faults are applied to two identical induction motors in lab ...
M. Z. Ali +4 more
semanticscholar +1 more source
A Novel Fault Diagnosis Scheme Based on Local Fault Currents for DC Microgrids
IEEE Transactions on Power DeliveryThe diversity of line fault types, the uncertainty of fault resistances, the limitation of available fault information, and the similarity of positive pole currents under different work conditions challenge the fault diagnosis of DC microgrids.
Weiwei Li +7 more
semanticscholar +1 more source
Fault-Current Measuring Device
Transactions of the American Institute of Electrical Engineers, 1946IN electric power system operation numerous problems are encountered in analyzing the results of short circuits and in the physical location of the trouble. Some devices now available for analyzing short circuits in a-c circuits are the oscillograph, the annunciator ammeter, and a magnetic link device requiring rectifiers.
openaire +1 more source
IGBT Fault Current Limiting Circuit
IEEE Industry Applications Magazine, 1995Circuits are proposed which, by limiting the fault current magnitude, extends the short-circuit withstand time of high-efficiency (high-gain) IGBTs (insulated-gate bipolar transistors). Limiting of the fault current magnitude also results in reduced turn-off voltage transients, a desirable byproduct, especially for higher current modules. Moreover, the
R. Chokhawala, G. Castino
openaire +1 more source
Multicell Fault Current Limiter
IEEE Transactions on Industrial Electronics, 2014A multicell fault current limiter (MCFCL) is proposed in this paper. The MCFCL is composed of multiple fault current limiting cells. Each fault current limiting cell consists of a fault current limiting inductor and a power electronic module. The proposed MCFCL has the flexibility in expanding the operation voltage by increasing the number of fault ...
Wenyong Guo +6 more
openaire +1 more source
Superconducting fault current limiters
IEE Colloquium on High Tc Superconducting Materials as `Magnets', 1995Fault current limiters (FCLs), superconducting or otherwise, have the potential to reduce fault levels on electricity power networks, and may ultimately lead to lower rated components (i.e. cheaper) being used, or to increased capacity on existing systems.
openaire +2 more sources
Superconducting fault current limiters
IEEE Power Engineering Review, 2000Events in the power utility industry, such as deregulation, demands for better power quality and reliability, the advent of high temperature superconductivity, and the push to use technology to realize greater profits, have renewed interest in fault current limiters (FCL).
openaire +1 more source
Fault-resistance effect on ground fault current
Electrical Engineering, 1953GROUND FAULT currents may be reduced substantially when fault resistance is included in the fault circuit. The majority of faults that occur on a power system involve ground and occur between conductor and tower. When a fault occurs to a steel tower or grounded wood pole on a grounded system the footing resistance is included automatically in the fault
openaire +1 more source
Fault current contribution of DFIG under unsymmetrical fault
2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), 2011In this paper, the transient characteristics of double-fed induction generator (DFIG) are analyzed. Based on this, the fault current contribution of DFIG with and without crowbar are compared. Comparison result shows that fault current of DFIG under different ride-through conditions differs widely from each other.
Zheng-rong Wu +4 more
openaire +1 more source