An Adaptive Series-Dynamic-Resistor-Based Protection Scheme for Brushless Doubly- Fed Induction Generator Under Asymmetrical Fault Conditions

open access: yesIEEE Access
Low-voltage ride-through (LVRT) is one of the most important criteria for integrating wind energy into the power grid. Based on grid connection codes, wind generators must remain connected during fault conditions.
Mahyar Gholizadeh   +5 more
doaj   +1 more source

Fault Ride-Through Capability of DSTATCOM for Distributed Wind Generation System

open access: yesInternational Journal of Power Electronics and Drive Systems (IJPEDS), 2015
<span>In this paper, fault ride through analysis of a low voltage distribution system augmented with distributed wind generation using squirrel cage induction generator and distribution static compensator (DSTATCOM) is carried out through modeling and simulation study in MATLAB.
Manju Aggarwal   +2 more
openaire   +1 more source

Enhancing LVRT Capability of DFIG-Based Wind Turbine Systems with SMES Series in the Rotor Side

open access: yesInternational Journal of Rotating Machinery, 2017
The necessary Low Voltage Ride Through (LVRT) capability is very important to wind turbines. This paper presents a method to enhance LVRT capability of doubly fed induction generators- (DFIGs-) based wind turbine systems with series superconducting ...
Xiao Zhou, Yuejin Tang, Jing Shi
doaj   +1 more source

Fault ride-through of renewable energy conversion systems during voltage recovery

open access: yesJournal of Modern Power Systems and Clean Energy, 2016
Asymmetrical voltage swells during recovery of a short-circuit fault lead to fluctuations in the dc-link voltage of a renewable energy conversion system (RECS), and may induce reversed power flow and even trip the RECS. This paper studies characteristics
Ruiqi Li, Hua Geng, Geng Yang
doaj   +1 more source

A modular DC transformer with DC fault ride-through capability

open access: yesJournal of Physics: Conference Series
Abstract DC transformers are core equipment for constructing multi-voltage-level DC distribution networks. However, mainstream DC transformer topologies, which are based on the Input-Series Output-Parallel Dual Active Bridge (ISOP-DAB), currently have deficiencies in fault blocking capability and fault-tolerant redundancy design.
Jiejie Zhou   +5 more
openaire   +1 more source

FAULT RIDE-THROUGH CAPABILITY AND DAMPING IMPROVEMENT IN DFIG

open access: yes, 2016
Doubly-fed induction generator wind turbine is susceptible to faults and requires crowbar protection. When the crowbar is triggered, the rotor is short circuited over the crowbar impedance. Then, the doubly-fed induction generator operates as a squirrel-cage induction generator that tends to absorb large amount of reactive power from the grid during ...
M. Q. DUONG   +5 more
openaire   +1 more source

A comprehensive coordinated control strategy of MMC-HVDC system for frequency support and DC overvoltage suppression

open access: yesInternational Journal of Electrical Power & Energy Systems
To enhance frequency support and fault ride-through capabilities of MMC-HVDC system, an MMC multi-time scale coordinated control strategy considering the regulation dead zone is proposed, which achieves wide-area coordinated complementarity of multiple ...
Shouqi Jiang   +5 more
doaj   +1 more source

Asymmetric fault voltage support scheme for soft open points based on improved negative sequence voltage outer loop

open access: yes电力工程技术
Flexible interconnection and dynamic power flow regulation in distribution networks are achieved by soft open point (SOP), optimizing the configuration and scheduling of distribution resources. To improve the load voltage during asymmetric ground faults,
Xuze WANG, Wu CHEN, Haixi ZHAO, Shi CHEN
doaj   +1 more source

Power angle based fault recovery analysis for grid-connected GFM inverters with current limiting

open access: yesInternational Journal of Electrical Power & Energy Systems
To meet both the requirements of current limiting and ancillary services during fault ride-through (FRT) of the GFM inverters, various current limiting strategies are developed.
Jialun Yang   +5 more
doaj   +1 more source

A Novel Self-Protective Transformer Using a Fault Current Limiter Approach

open access: yesIEEE Access
Transformers are essential components of distribution systems but are vulnerable to fault currents, posing significant challenges for their protection.
Sajjad Agheli   +2 more
doaj   +1 more source