Results 41 to 50 of about 143,516 (307)

Femoral neck shortening after internal fixation

open access: yesActa Orthopaedica et Traumatologica Turcica, 2020
Objective: The aim of this study was to assess the factors affecting femoral neck shortening after internal fixation of femoral neck fractures.\r\nMethods: Eighty-six patients with femoral neck fractures were treated using three parallel cannulated ...
Yue Liu   +3 more
doaj   +1 more source

Biomechanical Study Using the Finite Element Method of Internal Fixation in Pauwels Type III Vertical Femoral Neck Fractures [PDF]

open access: yes, 2015
Background: Several factors are known to influence osseous union of femoral neck fractures. Numerous clinical studies have reported different results, hence with different recommendations regarding treatment of Pauwels III fractures: femoral neck ...
Adachi, K.   +5 more
core   +1 more source

Prediction of hip joint function and analysis of risk factors for internal fixation failure after Femoral Neck System (FNS)

open access: yesBMC Musculoskeletal Disorders, 2023
Objective Analysis of the risk factors affecting hip function and complications after femoral neck system (FNS) surgery for femoral neck fractures is of great significance for improving the procedure’s efficacy.
Yazhong Zhang   +8 more
doaj   +1 more source

Hip Morphology–Based Osteoarthritis Risk Prediction Models: Development and External Validation Using Individual Participant Data From the World COACH Consortium

open access: yesArthritis Care &Research, EarlyView.
Objective This study aims to develop hip morphology‐based radiographic hip osteoarthritis (RHOA) risk prediction models and investigates the added predictive value of hip morphology measurements and the generalizability to different populations. Methods We combined data from nine prospective cohort studies participating in the Worldwide Collaboration ...
Myrthe A. van den Berg   +26 more
wiley   +1 more source

Bone-to-bone and implant-to-bone impingement : a novel graphical representation for hip replacement planning [PDF]

open access: yes, 2020
Bone-to-bone impingement (BTBI) and implant-to-bone impingement (ITBI) risk assessment is generally performed intra-operatively by surgeons, which is entirely subjective and qualitative, and therefore, lead to sub-optimal results and recurrent ...
Elliott, Mark T.   +6 more
core   +1 more source

Characterization of an Injectable Poly(vinyl alcohol)‐gelatin Hydrogel for Growth Factor Delivery in an Orthopedic Application

open access: yesAdvanced Healthcare Materials, EarlyView.
This work introduces photo‐crosslinkable tyraminated poly(vinyl alcohol)‐gelatin (PVA‐GT) hydrogels as tunable injectable platforms for tissue engineering and growth factor delivery applications. This schematic illustrates the two developed hydrogel formulations and the experimental workflow used to evaluate their physico‐chemical properties in vitro ...
Alessia Longoni   +15 more
wiley   +1 more source

STRUCTURAL PECULIARITIES OF PROXIMAL HIP BONE AS RISK FACTOR OF HIP FRACTURES IN IRKUTSK POPULATION

open access: yesНаучно-практическая ревматология, 2002
Objective. To investigate the several parameters of femoral neck geometry associated with hip fracture risk in Siberial population. Material anil methods.
L. V. Menshikova, N A Khramtzova
doaj   +1 more source

Lattice Structures for Bone Replacement: The Intersection of Bone Biomechanics, Lattice Design, and Additive Manufacturing

open access: yesAdvanced Materials Technologies, EarlyView.
This review outlines how understanding bone's biology, hierarchical architecture, and mechanical anisotropy informs the design of lattice structures that replicate bone morphology and mechanical behavior. Additive manufacturing enables the fabrication of orthopedic implants that incorporate such structures using a range of engineering materials ...
Stylianos Kechagias   +4 more
wiley   +1 more source

Ultra‐Thin Soft Pneumatic Actuation for Minimally Invasive Neural Interfacing

open access: yesAdvanced Materials Technologies, EarlyView.
Parylene C is a common polymer in bioelectronics, favored for its biological and chemical inertness. However, this makes bonding layers of Parylene C together very challenging. Here it is a laser to selectively weld layers of Parylene C to create high‐pressure fluidic actuation devices.
Lawrence Coles   +4 more
wiley   +1 more source

Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures

open access: yesBMC Musculoskeletal Disorders, 2023
Objective To design a cross-inverted triangular pattern to insert compression screw nails for the treatment of femoral neck fractures and to compare the biomechanics of inserting compression screw nails in cross-inverted triangular patterns and inverted ...
Min Wang   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy