Results 171 to 180 of about 515,490 (195)

Predicting femoral neck screw pullout strength using DXA and novel assessments of bone microarchitecture. [PDF]

open access: yesArch Osteoporos
Moyer J   +8 more
europepmc   +1 more source

Femoral neck shortening as a sequela of internal fixation for femoral neck fractures and its effect on the coronal alignment of the limb: a pilot study

Archives of Orthopaedic and Trauma Surgery, 2023
Femoral neck shortening is a common phenomenon following osteosynthesis for femoral neck fractures, which was shown to have a negative effect on hip function. There is paucity of literature on the effect of shortening on the ipsilateral limb mechanical axis and knee coronal alignment. We hypothesized that postoperative femoral neck shortening can alter
Yoav Rosenthal, Shai Shemesh
exaly   +3 more sources

Shortening after Femoral Neck Fracture Fixation

Clinical Orthopaedics and Related Research, 2007
When using parallel screws for treatment of femoral neck fractures, shortening of the femoral neck might occur. Given the high revision surgery rates associated with parallel screws, we developed a questionnaire to explore (1) surgeons' viewpoints on difficulties in the fixation of femoral neck fractures, (2) their perception of the clinical importance
Philip J Kregor
exaly   +3 more sources

Sequential scintigraphy and orthoradiographic measurement of femoral shortening after femoral neck fracture

Archives of Orthopaedic and Trauma Surgery, 1997
The objective of the study was to assess scintigraphic patterns and femoral shortening after femoral neck fracture in order to select predictive parameters for late complications. Eighty-eight patients with osteosynthesized femoral neck fractures were followed for 2 years with regular scintigraphic evaluations and orthoradiographic measurements of ...
K Messner
exaly   +3 more sources

Femoral Neck Shortening and Varus Collapse After Navigated Fixation of Intracapsular Femoral Neck Fractures

Journal of Orthopaedic Trauma, 2012
Assessing femoral neck shortening (FNS) and varus collapse after internal fixation of femoral neck fractures using computerized navigation (CN).Retrospective cohort study.Academic Level I trauma center.Forty-one patients who had healed femoral neck fractures treated with CN between the years 2003 and 2008. Average age was 65 years (range, 14-91 years).
Amal Khoury   +2 more
exaly   +3 more sources

Comparison of femoral neck shortening after femoral neck system and cannulated cancellous screw fixation for displaced femoral neck fractures in young adults

Injury
The purpose of this study was to compare the outcomes of femoral neck shortening between the femoral neck system (FNS) and the cannulated cancellous screws (CCS) for displaced femoral neck fractures in young adults PATIENTS AND METHODS: In this retrospective analysis, 225 patients aged 18-65 years with displaced femoral neck fracture were divided into ...
Peisheng Chen   +2 more
exaly   +3 more sources

Femoral Neck Shortening After Fracture Fixation With Multiple Cancellous Screws: Incidence and Effect on Function

Journal of Trauma, 2008
Shortening of the femoral neck after fracture fixation with multiple parallel screws decreases the moment arm for the abductor muscles of the hip. This study aimed to assess the incidence of femoral neck shortening quantitatively and qualitatively in patients with femoral neck fractures treated with multiple cannulated screws, and to investigate its ...
Brad Petrisor, Olufemi Ayeni
exaly   +3 more sources

Additional file 1 of Incidence and factors influencing neck shortening after screw fixation of femoral neck fractures with the femoral neck system

2023
ملف إضافي 1. محتوى بيانات هذه الدراسة.
Kai Wang   +10 more
openaire   +1 more source

Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures

Archives of Orthopaedic and Trauma Surgery, 2018
Femoral neck fractures (FNF) are becoming increasingly common as population ages. Nondisplaced fractures are commonly treated by cancellous, parallel placed, partially threaded cannulated screws (PTS). This allows controlled fracture impaction. However, sliding implants can lead to femoral neck shortening (FNS) that has been shown to be correlated with
Yoram A, Weil   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy