Results 171 to 180 of about 84,799 (276)
Radiographer Preliminary Image Evaluation Accuracy in Interpreting Paediatric Trauma Radiographs
Radiographer preliminary image evaluation (PIE) is a patient safety mechanism where radiographers provide a written comment describing potential pathology in radiographs they have acquired. This can assist emergency referrers in making a diagnosis when a radiologist's report is unavailable.
Teresa Poon, Michael Neep, Therese Gunn
wiley +1 more source
Objectives Intra‐amniotic sludge is an independent risk factor for preterm birth. It consists of a biophysical sonographic finding in the amniotic fluid, formed by dense echogenic particles near the cervical internal orifice, due to sterile or infectious inflammatory processes.
Clarissa Chavez Ortiz Roberto +8 more
wiley +1 more source
From Valgus-impacted to Displaced: Clinical and Technical Lessons in Femoral Neck Fracture Fixation with the Femoral Neck System. [PDF]
Kumar TKJ +4 more
europepmc +1 more source
Abstract Purpose To evaluate the safety and efficacy of intra‐articular autologous transplantation of adipose‐derived connective tissue micrografts rich in stromal vascular fraction (CTM‐SVF), obtained using an enzyme‐free system (Hy‐Tissue® SVF) for knee osteoarthritis (OA). Methods Thirty patients (mean age of 53.3 ± 6.4 years) with Kellgren–Lawrence
Laura Mangiavini +11 more
wiley +1 more source
Comparison of the femoral neck system and dynamic hip screw for femoral neck fracture: A systematic review and meta-analysis. [PDF]
Lim EJ +4 more
europepmc +1 more source
Femoral osteomyelitis caused by cladophialophora in a patient without known immunocompromise [PDF]
Boccichio, Grant V +6 more
core +2 more sources
Abstract Purpose A single hip–knee–ankle angle (HKA) angle does not reflect the biomechanics of native, arthritic or prosthetic knees. Since HKA varies throughout flexion, dynamic coronal alignment is best represented by a kinematic curve plotting HKA against the range of motion.
Petros Ismailidis +3 more
wiley +1 more source
Abstract Purpose Modern personalised total knee arthroplasty (TKA) techniques aim to mimic natural knee kinematics by focusing on soft‐tissue dynamics rather than static alignment. However, a consistent definition of the optimal ligamentous balance has not yet been established.
Michael Engl +9 more
wiley +1 more source
Comparing the Clinical and Radiological Outcome of Femoral Neck System Versus Dynamic Hip Screw in Femoral Neck Fractures. [PDF]
Kunwar A +5 more
europepmc +1 more source
ABSTRACT Purpose To improve accuracy of apparent diffusion coefficient (ADC) measurement across different bone‐marrow (BM) sites for myelofibrosis (MF) patients. Methods Vendor‐provided ADC gradient nonlinearity correction (GNC) was implemented for 41 MF study subjects on a 3T clinical scanner.
Dariya Malyarenko +9 more
wiley +1 more source

