Background Most displaced femoral neck fractures can achieve satisfactory anatomical reduction by closed reduction, but there are still some that cannot reset satisfactorily after closed reduction, and open reduction are required.
Chengzhi Liang +5 more
doaj +3 more sources
Safe range of femoral neck system insertion and the risk of perforation [PDF]
Background Internal fixation of the femoral neck carries a risk of perforation due to the presence of the isthmus of the femoral neck. At present, there are few studies on the safe and risk zones of the femoral neck system (FNS) implantation.
Mingxuan Han +3 more
doaj +2 more sources
Clinical application of the femoral neck system in the treatment of femoral neck fractures [PDF]
ObjectiveThe research was conducted to assess the therapeutic efficacy of the femoral neck system (FNS) and cannulated compression screw (CCS) in treating femoral neck fractures classified as Pauwels type II and III in young to middle-aged patients ...
Guangyao Li +7 more
doaj +2 more sources
Clinical application of the Femoral Neck System in femoral neck fractures
Hao Zeng +3 more
doaj +3 more sources
Reduction of complications in femoral neck fracture fixation using femoral neck system: the importance of pre-compression technique and power bar position [PDF]
BackgroundTo explore the causes of early- and mid-term complications and failures following femoral neck system (FNS) treatment for femoral neck fractures in young and middle-aged adults, to identify prevention and treatment strategies.MethodA ...
Bin Chen +7 more
doaj +2 more sources
Comparative study on the clinical efficacy of femoral neck system and cannulated cancellous screw in the treatment of femoral neck fractures in young patients [PDF]
Objective To investigate the clinical efficacy of femoral neck system and hollow compression screw in the treatment of femoral neck fractures in young patients. Methods and materials A retrospective study was conducted on young patients with femoral neck
Wenbin Ding +6 more
doaj +2 more sources
Comparable results for the Femoral Neck System and three-screw fixation in femoral neck fracture treatment. [PDF]
Abstract Objectives: To report outcomes of femoral neck fractures (FNFs) treated with Femoral Neck System (FNS) and to compare the risks of later conversion to arthroplasty for FNS and fixation with cannulated screws (CNSs). Design: A retrospective study.
Honkanen J +7 more
europepmc +4 more sources
Femoral neck system versus cannulated screws with a medial plate for the fixation of Pauwels type III femoral neck fractures in young patients: a retrospective cohort study [PDF]
Objectives The purpose of this study was to compare the efficacy of femoral neck system (FNS) and cannulated screws with a medial plate (CSMP) for Pauwels type III femoral neck fractures in young adults.
Dilixiati Duolikun +5 more
doaj +2 more sources
Novel internal fixation technique for Pauwels type III neck of femur fractures using the femoral neck system in conjunction with a medial buttress plate: a case report [PDF]
. Background:. Femoral neck fractures in patients under 50 years of age are rare and primarily associated with high energy trauma. We documented the use of a novel internal fixation technique to manage a Pauwels type III fracture, which presents ...
Devonny Sherwood, MBBS +1 more
doaj +2 more sources
Optimal sliding distance in femoral neck system for displaced femoral neck fractures: a retrospective cohort study. [PDF]
Displaced femoral neck fractures frequently result in considerable patient morbidity, with complications such as postoperative femoral neck shortening occurring in up to 39.1% of cases. This shortening is associated with reduced hip function and mobility.
Weng S +7 more
europepmc +4 more sources

