Results 1 to 10 of about 131 (90)
ABSTRACT Cross‐scale assembly of metal (sub) nanoparticles and/or single atoms into millimeter/nanostructured metal monolithic catalysts (Min‐SMCs) is highly appealing for sustainable water cleanup, due to energy‐efficient catalyst recyclability, high infrastructure compatibility, and low metal‐releasing risks.
Jia‐Cheng E. Yang +4 more
wiley +1 more source
ABSTRACT Platinum (Pt)‐based catalysts are crucial for the commercialization of hydrogen/metal air batteries, but they suffer from Pt scarcity, high cost, and nanoparticle dissolution/agglomeration, mainly leading to performance degradation. We address this by synthesizing a PtFe alloy catalyst (PtFe–PA–NC) via a phytic acid (PA) assisted pyrolysis ...
Chenyang Shu +9 more
wiley +1 more source
ABSTRACT The covalent bonds at heterojunction interfaces enable more efficient charge carrier separation than traditional weakly coupled heterojunctions, with enhanced photocatalytic performance for organic wastewater purification. The interfacial covalent bonds drive energy band reorganization, rendering the conventional independent band edge ...
Jing‐Yu Ren +5 more
wiley +1 more source
采用微波辐射Fenton试剂处理TNT废水,分别考察了TNT废水初始浓度、双氧水用量、微波辐射时间、微波功率和pH等因素对TNT废水处理效果的影响。结果表明,在微波功率为480 W、微波辐射时间为6 min、6%的双氧水用量为1.5 mL、FeSO4质量为0.07 g和pH=4的条件下,TNT废水COD去除率达到84.5%。单独微波辐射、单独Fenton试剂氧化、微波辐射Fenton试剂3种不同方法的对比实验表明,微波辐射Fenton试剂有明显的优越性。
关晓彤 +6 more
doaj
采用Fenton试剂为主体的高级氧化法,分别比较了UV-Fenton和US-Fenton两种常见的高级氧化技术对偶氮染料废水的深度处理效果及理论能耗。结果表明,当染料质量浓度在400 mg/L时,UV-Fenton和US-Fenton均可使偶氮染料废水的脱色率达到95%以上,综合理论试剂投加费用、耗电量以及反应时间等因素,US-Fenton拥有更好的应用前景。
赵菁 +6 more
doaj
采用Fenton试剂氧化-水解酸化-Biofor(一段式生物过滤氧化反应器)工艺处理硝基苯胺类农药废水。结果表明:Fenton试剂氧化CODCr去除率为73.8%,色度去除率为88.7%;水解酸化-Biofor工艺处理CODCr去除率在20%~60%,色度去除率为63.9%,在总进水CODCr≤19 870 mg/L、色度≤20 000倍时,采用Fenton试剂氧化-水解酸化-Biofor工艺,加入适当的冷却水稀释盐分,处理后出水CODCr<100 mg/L、色度<50倍。
朱乐辉 +4 more
doaj
研究了用Fenton试剂处理阿奇霉素废水的影响因素及适宜工艺条件.试验表明,用Fenton试剂处理阿奇霉素废水的最佳实验条件:反应温度为25℃、pH为3.0、FeSO4投加量为10mL/L、H2O2投加量为30mL/L、氧化时间为2.0h.在此条件下,其对COD的平均去除率达51.09%.
程建锋 +5 more
doaj
采用“外加磁场+强化混凝+络合除氟”的改良型Fenton工艺对制药园区污水处理厂生化出水进行深度处理中试,重点研究改良型Fenton工艺对有机物、悬浮物、总磷的去除效果,以及耦合络合除氟后对氟化物的协同去除效果。与传统Fenton工艺对比实验结果表明,相同加药量条件下改良型Fenton工艺处理效果更好,而控制相同处理水质条件下,改良型Fenton工艺药剂消耗更少。中试实验结果表明,改良型Fenton工艺运行稳定,对多种污染物协同增效去除效果显著,在中试系统进水COD、SS、TP、F ...
洪卫 +7 more
doaj
采用破乳-Fenton试剂法对机械厂磨床车间废乳化液进行处理(原水CODCr=290000mg/L,BOD5=28000mg/L)。结果表明:使用合适的破乳药剂,破乳后废水的CODCr去除率达到97.8%;之后投加适量的Fenton试剂进行氧化处理,最终出水CODCr为684mg/L;BOD5/COD由0.094增至0.47,可生化性大大提高。
王浪 +4 more
doaj
采用超声波为辅助条件,以废水的COD去除率、脱色率为评价指标,考察了Fenton试剂对糖蜜酒精废水催化降解特性。实验结果表明,Fenton试剂对糖蜜酒精废水具有良好的处理效果,超声波与Fenton试剂之间存在着协同作用。通过正交实验得出的最佳降解工艺条件为:H2O2用量10mL/L,硫酸亚铁0.50g/L,废水稀释倍数40倍,超声波功率200W,反应时间30min,废水的COD去除率达到69%,色度降解率达到74%。
曾玉凤, 刘自力, 秦祖赠, 龙峰
doaj

