Results 91 to 100 of about 30,351 (276)

Series production technology for high-performance fibre composite components with structure integrated sensors

open access: yesComputer Assisted Methods in Engineering and Science, 2022
The integration of electronic units, sensors and actuators into complex function-oriented systems is one of the key points in the development of intelligent fibre composites.
Lothar Kroll   +2 more
doaj  

Harnessing Fungal Biowelding for Constructing Mycelium‐Engineered Materials

open access: yesAdvanced Engineering Materials, EarlyView.
Mycelium‐bound composites (MBCs) offer low‐carbon alternatives for construction, yet interfacial bonding remains a critical challenge. This review examines fungal biowelding as a biocompatible adhesive, elucidating mycelium‐mediated interfacial mechanisms and their role in material assembly. Strategies to optimize biowelding are discussed, highlighting
Xue Brenda Bai   +2 more
wiley   +1 more source

Quantitative sensitivity analysis of surface attached optical fiber strain sensor [PDF]

open access: yes, 2014
Optical fiber strain sensors, in particular, the fiber Bragg grating (FBG) type, are widely applied in different applications. The most common installation method is surface-attached.
Wan, KT
core   +1 more source

A Novel Fabry-Pérot Optical Sensor for Guided Wave Signal Acquisition

open access: yesSensors, 2020
In this paper, a novel hybrid damage detection system is proposed, which utilizes piezoelectric actuators for guided wave excitation and a new fibre optic (FO) sensor based on Fabry-Perot (FP) and Fiber Bragg Grating (FBG).
Cheng Xu, Zahra Sharif Khodaei
doaj   +1 more source

Innovative Processing of Compacted Waste Aluminum Alloy Powders via Controlled Remelting and Solidification

open access: yesAdvanced Engineering Materials, EarlyView.
This study demonstrates an efficient recycling route for out‐of‐spec AlSi10Mg atomized powders through compaction and arc remelting followed by suction casting. By correlating compaction load, cooling rate, and resulting microstructure, we show that intermediate pressures (50–80 kN) and rapid cooling refine dendrites, reduce porosity, and enhance ...
Mila Christy de Oliveira   +4 more
wiley   +1 more source

Laboratory tests of measurement systems in pile shafts

open access: yesSoils and Foundations
The article describes the results of laboratory tests of reinforced concrete pile sections instrumented with several measurement systems. Compression tests were carried out on three 300-mm-by-1.2-m cylindrical pile elements, reinforced with an IPE140 ...
Adam Jabłonowski   +2 more
doaj   +1 more source

Characterization of Nitinol Produced by Laser Powder Bed Fusion for Mechanical Metamaterial Applications

open access: yesAdvanced Engineering Materials, EarlyView.
Stabilization of L‐PBF Ni50.7Ti49.3 under low‐cycle loading was investigated. Recoverable strain after cycling was dependent on the amount of applied load. Recovery ratio was 53.4% and 35.1% at intermediate and high load, respectively. The maximum total strain reached 10.3% at a high load of 1200 MPa.
Ondřej Červinek   +5 more
wiley   +1 more source

Errors in Chemical Sensor Measurements

open access: yesSensors, 2001
Various types of errors during the measurements of ion-selective electrodes, ionsensitive field effect transistors, and fibre optic chemical sensors are described.
Artur Dybko
doaj   +1 more source

Influence of an Argon/Silane Atmosphere on the Temperature of a Thermal Plasma

open access: yesAdvanced Engineering Materials, EarlyView.
The influence of a silane‐doped argon atmosphere on the chemical composition and temperature of a thermal nontransferring argon plasma is investigated using optical emission spectroscopy. As a result of the high amount of free electrons resulting from the stepwise ionization and dissociation of the silane molecule, even a silane addition of 0.01 vol ...
Lena Kreie   +4 more
wiley   +1 more source

Use of polyethylene glycol coatings for optical fibre humidity sensing [PDF]

open access: yes, 2008
Humidity induced change in the refractive index and thickness of the polyethylene glycol (PEG) coatings are in situ investigated for a range from 10 to 95%, using an optical waveguide spectroscopic technique.
B. D. Gupta   +31 more
core   +2 more sources