Results 31 to 40 of about 18,198 (165)

Dosimetric effect of silicone‐based gel on skin surface during volumetric modulated arc therapy for breast cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to quantify and compare the dosimetric effects of varying thicknesses of StrataXRT, a silicone‐based gel, and other topical agents on the skin surface during volumetric modulated arc therapy (VMAT) for breast cancer.
Tenyoh Suzuki   +13 more
wiley   +1 more source

Detecting 6 MV X-rays using an organic photovoltaic device [PDF]

open access: yes, 2009
An organic photovoltaic (OPV) device has been used in conjunction with a flexible inorganic phosphor to produce a radiation tolerant, efficient and linear detector for 6 MV Xrays.
Harris, L.   +4 more
core   +1 more source

Evaluation of dosimetric and spatial accuracy of a virtual cone technique for radiosurgery using linac‐integrated CBCT‐based polymer gel dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab   +6 more
wiley   +1 more source

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance

open access: yes, 2004
A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap of 0.5 mm.
A Iglesias   +20 more
core   +1 more source

Fricke and polymer gel 2D dosimetry validation using Monte Carlo simulation [PDF]

open access: yes, 2016
Complexity in modern radiotherapy treatments demands advanced dosimetry systems for quality control. These systems must have several characteristics, such as high spatial resolution, tissue equivalence, three-dimensional resolution, and dose-integrating ...
Chacón Obando, D.   +12 more
core   +1 more source

Log file‐based quality assurance method for respiratory gating system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon   +7 more
wiley   +1 more source

Seasonal Minimum and Maximum Solar Ultraviolet Exposure Measurements of Classroom Teachers Residing in Tropical North Queensland, Australia [PDF]

open access: yes, 2019
The risk of keratinocyte skin cancer, malignant melanoma and ultraviolet radiation (UVR)-induced eye disease is disproportionately higher in Australia and New Zealand compared to equivalent northern hemisphere latitudes.
Berhard   +35 more
core   +1 more source

Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White   +5 more
wiley   +1 more source

Dosimetric characteristics of a new linear accelerator under gated operation. [PDF]

open access: yes, 2006
Respiratory gated radiotherapy may allow reduction of the treatment margins, thus sparing healthy tissue and/or allowing dose escalation to the tumor. However, current commissioning and quality assurance of linear accelerators do not include evaluation ...
Kriminski, Sergey   +2 more
core   +1 more source

Home - About - Disclaimer - Privacy