Purpose. To assess differences in dose distribution of a vertebral body injected with bone cement as calculated by radiation treatment planning system (RTPS) and actual dose distribution. Methods.
Atsushi Komemushi +10 more
doaj +1 more source
Proper dosimetry settings are crucial in radiotherapy to ensure accurate radiation dose delivery. This work evaluated scanning parameters as affecting factors in reading the dose-response of EBT2 and EBT3 radiochromic films (RCFs) irradiated with ...
Nashrulhaq Tagiling +5 more
doaj +1 more source
Background and Objectives: Quality assurance is an integral part of brachytherapy. Traditionally, radiographic films have been used for source position verification, however, in many clinics, computerized tomography simulators have replaced conventional ...
Songül Çavdar Karaçam +4 more
doaj +1 more source
Comparison of the 2-D Dose Distribution Calculated by Planning System and Measured by Gafchromic Film Physical Dosimetry for 60Co and 192Ir Brachytherapy Sources [PDF]
Background: High Dose Rate (HDR) brachytherapy sources with high photon energy have been widely used in treating tumors. Dosimetric parameter of these brachytherapy sources should be determined according to the AAPM TG-43 recommendation.
M H Gholami +3 more
doaj +1 more source
Dosimetry, personal monitoring film
The article focuses on radiation dosimetry, which made use of the photographic film known as Type 2 Monitoring Film (Kodak) to detect and measure harmful ionizing radiation. It explores the implications of the demise of this technology in relation to Henri Van Lier's critique of photographic indexicality in his paper "Towards a Philosophy Instigated by
Stephens, Tim, Pantridge, Keith
openaire +2 more sources
Dosimetry for small fields in stereotactic radiosurgery using gafchromic MD-V2-55 film, TLD-100 and alanine dosimeters. [PDF]
This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma
Guerda Massillon-J L +4 more
doaj +1 more source
Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and ...
Zwierzchowski Grzegorz +2 more
doaj +1 more source
Small field dosimetry for the small animal radiotherapy research platform (SARRP)
Background Preclinical radiation biology has become increasingly sophisticated due to the implementation of advanced small animal image guided radiation platforms into laboratory investigation.
Mihaela Ghita +11 more
doaj +1 more source
Fricke and polymer gel 2D dosimetry validation using Monte Carlo simulation [PDF]
Complexity in modern radiotherapy treatments demands advanced dosimetry systems for quality control. These systems must have several characteristics, such as high spatial resolution, tissue equivalence, three-dimensional resolution, and dose-integrating ...
Chacón Obando, D. +12 more
core +1 more source
Surface and buildup region dose measurements with Markus parallel-plate ionization chamber, Gafchromic EBT3 film and MOSFET detector for high energy photon beams [PDF]
The aim of the study was to investigate surface and buildup region doses for 6MV and 15MV photon beams using a Markus parallel-plate ionization chamber, GafChromic EBT3 film, and MOSFET detector for different field sizes and beam angles. The measurements
Akbas, Ugur +3 more
core +3 more sources