Technical innovation changes standard radiographic protocols in veterinary medicine: is it necessary to obtain two dorsoproximal-palmarodistal oblique views of the equine foot when using computerised radiography systems? [PDF]
Since the 1950s, veterinary practitioners have included two separate dorsoproximal–palmarodistal oblique (DPr–PaDiO) radiographs as part of a standard series of the equine foot.
Bolt, D M +5 more
core +1 more source
Given the sensitivity of proton therapy to anatomical variations, this cancer treatment modality is expected to benefit greatly from integration with magnetic resonance (MR) imaging.
Bussmann, Michael +5 more
core +1 more source
Overview of the sensitivity of Ge- and Al-doped silicon dioxide optical fibres to ionizing radiation [PDF]
This paper reviews the thermoluminescence sensitivity of Ge- and Al- doped SiO2 optical fibre subjected to various ionizing radiations. It is found that the Ge- doped SiO2 optical fiber has the thermoluminescence response superior to Al-doped SiO2 ...
Hashim, Suhairul +3 more
core +1 more source
Model selection for radiochromic film dosimetry [PDF]
The purpose of this study was to find the most accurate model for radiochromic film dosimetry by comparing different channel independent perturbation models. A model selection approach based on (algorithmic) information theory was followed, and the results were validated using gamma-index analysis on a set of benchmark test cases.
openaire +3 more sources
A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap of 0.5 mm.
A Iglesias +20 more
core +1 more source
Determination of Calibration Curve and Accurate Assessment of Error and Uncertainty in Radiochromic EBT2 Film Dosimetry [PDF]
In radiotherapy, the delivered dose to a target tissue should be of high accuracy, where any inaccuracy in the delivered dose can affect the treatment outcomes.
F Abbasi Davani +4 more
doaj
Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film [PDF]
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (
Seyed Mohsen Hosseini Daghigh +6 more
doaj +1 more source
Application of a Portable Colorimeter for Reading a Radiochromic Film for On-Site Dosimetry
Radiochromic films have widely been used for quality assurance (QA) in radiation therapy and have many advantageous features such as self-developing visible coloration, wide dose range and easiness to handle.
Hiroshi Yasuda, Hikaru Yoshida
doaj +1 more source
Companding technique for high dynamic range measurements using gafchromic films
We propose a methodology to perform dose measurements using gafchromic films which can span several decades of dose levels. The technique is based on a rescaling approach using different films irradiated at different dose levels.
Battum +13 more
core +1 more source
Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations [PDF]
Ion chamber dosimetry is being used to calibrate dose for cell irradiations designed to investigate photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility.
Alvarez, Diane +4 more
core +4 more sources