Novel X-ray imaging technology enables significant patient dose reduction in interventional cardiology while maintaining diagnostic image quality [PDF]
Objectives: The purpose of this study was to quantify the reduction in patient radiation dose during coronary angiography (CA) by a new X-ray technology, and to assess its impact on diagnostic image quality.
Bacher, Klaus +9 more
core +1 more source
In 2020, our institution transitioned to the Eclipse™ treatment planning system and to Truebeam® linear accelerators with 6 MV and 10 MV energies. The linear accelerators were installed in smaller bunkers that could not accommodate 400 cm FAD. A multidisciplinary team within the institution was created to evaluate existing total body irradiation ...
Gabriella La Macchia +5 more
wiley +1 more source
Design and dosimetric characterization of a transportable proton minibeam collimation system
BackgroundProton Minibeam Radiation Therapy has shown to widen the therapeutic window compared to conventional radiation treatment in pre-clinical studies.
Mabroor Ahmed +17 more
doaj +1 more source
This study develops a method combining radiochromic film and image processing to assess HDR brachytherapy source accuracy and linearity, achieving high precision and efficiency . Abstract Purpose To develop and validate a fully automated quality assurance method for high‐dose rate (HDR) brachytherapy, enabling the precise evaluation of source dwell ...
Qingqing Yuan +4 more
wiley +1 more source
An elderly male patient with extramammary Paget disease of the scrotum and multiple metastases was treated with fractionated FLASH‐RT (40 Gy in 5 fractions) in the scrotal lesion. Abstract Objective Ultrahigh‐dose‐rate radiotherapy (FLASH‐RT) has been shown to reduce radiation‐induced normal tissue injury in preclinical studies.
Hui Luo +14 more
wiley +1 more source
Implementation and validation of 2-D-array based tests in routine linac quality assurance
Purpose: In medical linac quality assurance (QA), to replace film dosimetry with low-resolution 2-D ionization chamber array measurements, to validate the procedures, and to perform a comprehensive sensitivity analysis.
Jiří Valenta +2 more
doaj +1 more source
Measurement of Collimator Scatter Factor for Photon Fields Using Gafchromic EBT2 Film and Ion Chamber [PDF]
Background and Objective: In radiotherapy, measurement of the output factor in the air is one of the input parameters for Implementation of treatment planning systems and beam modeling.
Asgarian Dehkordy, Zeinab. +5 more
core
Towards 3D printed multifunctional immobilization for proton therapy: initial materials characterization [PDF]
Purpose: 3D printing technology is investigated for the purpose of patient immobilization during proton therapy. It potentially enables a merge of patient immobilization, bolus range shifting, and other functions into one single patient-speci c structure.
Ahn +44 more
core +2 more sources
Impact of Device Architecture on Proton Detection Efficiency in 2D Perovskite Thick Film Detectors
This work shows the role of device architecture in MeV proton detection with 2D perovskite thick (> 1 µm) films. A direct comparison between planar and stacked devices demonstrates that the stacked geometry achieves superior response by enabling more efficient charge collection and better exploitation of the active layer volume, ensuring stable and ...
Giulia Napolitano +5 more
wiley +1 more source
KARAKTERISTIK DOSIMETRI FILM GAFCHROMIC EBT3 PADA BERKAS ELEKTRON DAN FOTON
Abstrak Elektron energi tinggi bermanfaat dalam radioterapi target permukaan dapat pula digunakan sebagai eskalasi dosis sumber berkas foton. Dalam jaminan kualitas radioterapi membutuhkan dosimeteryang akurat, respon yang baik terhadapdosis dan ...
Syarifatul Ulya +3 more
doaj +1 more source