Results 221 to 230 of about 1,389,069 (290)
Efficient two‐photon resonant Raman scattering (TRRS) is observed in the layered perovskite (PEA)2PbI4, with the biexciton level acting as an intermediate state. TRRS undergoes two‐photon frequency shift upon input frequency tuning, persists up to 90 K, and shows clear threshold behavior and polarization selection rules.
Seung Han Shin +7 more
wiley +1 more source
A comparative 3D finite element analysis of mandibular advancement with clear aligners and twin block appliances. [PDF]
Durmus M, Bulut M, Hezenci Y.
europepmc +1 more source
Computational Modeling Meets 3D Bioprinting: Emerging Synergies in Cardiovascular Disease Modeling
Emerging advances in three‐dimensional bioprinting and computational modeling are reshaping cardiovascular (CV) research by enabling more realistic, patient‐specific tissue platforms. This review surveys cutting‐edge approaches that merge biomimetic CV constructs with computational simulations to overcome the limitations of traditional models, improve ...
Tanmay Mukherjee +7 more
wiley +1 more source
Sacroiliac Joint Stress Is Affected by Postural Change or Cam Resection in Femoroacetabular Impingement Syndromes: A Finite Element Analysis Study. [PDF]
Nagashima R +9 more
europepmc +1 more source
Understanding the Effects of Conductive Polymer Electrode Coating on Recorded Neural Signals
Conductive polymer coatings are widely explored to improve the quality of signals recorded with chronically implanted neural electrodes, offering enhanced biocompatibility along with reduced electrode impedance. Combining computational modelling and data from PEDOT:PTS coated and PtIr electrodes in rats, we show that improvements in signal quality with
Karthik Sridhar +4 more
wiley +1 more source
Impact of Various Sleeve Materials on Temperature Variations During Guided Endodontic Access Cavity Preparation Utilizing Finite-Element Analysis. [PDF]
Muryani A +5 more
europepmc +1 more source
xx xx. ABSTRACT Osseointegration of orthopedic and dental implants is influenced by local and systemic factors, including their physicochemical surface properties and the patient's overall health status. Titanium and its alloys have been a longstanding standard for bone implants due to their innate biocompatibility and mechanical properties.
Dainelys Guadarrama Bello +2 more
wiley +1 more source
Wound closure is governed by geometry‐orientation coupling: aligned fibers speed migration along their axis but hinder perpendicular advance. In vivo diabetic wound experiments with composition‐matched fibrin, combined with an anisotropic diffusion (biased random‐walk) model, quantify this trade‐off and generate a healing landscape.
Yin‐Yuan Huang +13 more
wiley +1 more source

