Results 61 to 70 of about 2,723,089 (250)

Behavior of one-way reinforced concrete slabs subjected to fire

open access: yesAlexandria Engineering Journal, 2013
A finite difference analysis was performed to investigate the behavior of one-way reinforced concrete slabs exposed to fire. The objective of the study was to investigate the fire resistance and the fire risk after extinguishing the fire.
Said M. Allam   +2 more
doaj   +1 more source

Influence of graphene on fire protection of intumescent fire retardant coating for steel structure

open access: yesEnergy Reports, 2020
Graphene (GR) was used as filler to improve the performance of fire resistance, thermal stability, smoke suppression of waterborne intumescent fire-retardant coating.
Wang Zhan   +3 more
doaj   +1 more source

Statewide fire service disaster response plan

open access: yes, 2010
Version 2.1.; Title from PDF cover (publisher's Web site, viewed June 2, 2011).; "December 2010."; Previously issued: Statewide fire-rescue disaster response plan / Connecticut Fire Service. [Windsor Locks, Conn.
Connecticut Fire Chiefs Association.
core  

Additively Manufactured Geometry‐Reconfigurable Soft Neural Probes With Monolithic Multifunctionality

open access: yesAdvanced Functional Materials, EarlyView.
A geometry‐reconfigured additive manufacturing strategy converts planar printed soft materials into soft compact neural probes with integrated hydrogel electrodes and microfluidic channels. The resulting NeuroMAP platform enables scalable multichannel recording, localized chemical delivery, stable in vivo electrophysiological recording, and reduced ...
Hyunjin Lee   +15 more
wiley   +1 more source

Connecticut Fire Academy training calendar; Connecticut Fire Academy course calendar

open access: yes, 2007
Annual; Harvested from the web on 3/18 ...
Connecticut Fire Academy.
core   +1 more source

Fire Resistance of Prefabricated Steel Tubular Columns with Membrane Protections

open access: yesBuildings
With the acceleration of construction industrialization and carbon reduction goals, prefabricated steel structures are widely used for their efficiency and strength. However, steel’s poor fire resistance limits its use.
Xinxin Zhang   +2 more
doaj   +1 more source

(Experimental behaviour on the fire performance of steel reinforced concrete (SRC) columns)

open access: yes, 2007
Steel reinforced concrete (SRC) column is being widely used in engineering structures. It is thus very important to understand the fire performance of this kind of composite structures.
Han, Lin-Hai   +2 more
core  

Bioinspired Adaptive Sensors: A Review on Current Developments in Theory and Application

open access: yesAdvanced Materials, EarlyView.
This review comprehensively summarizes the recent progress in the design and fabrication of sensory‐adaptation‐inspired devices and highlights their valuable applications in electronic skin, wearable electronics, and machine vision. The existing challenges and future directions are addressed in aspects such as device performance optimization ...
Guodong Gong   +12 more
wiley   +1 more source

Connecticut Fire Academy training calendar; Connecticut Fire Academy course calendar

open access: yes, 2011
Annual; Harvested from the web on 3/18 ...
Connecticut Fire Academy.
core   +1 more source

Neuromorphic Electronics for Intelligence Everywhere: Emerging Devices, Flexible Platforms, and Scalable System Architectures

open access: yesAdvanced Materials, EarlyView.
The perspective presents an integrated view of neuromorphic technologies, from device physics to real‐time applicability, while highlighting the necessity of full‐stack co‐optimization. By outlining practical hardware‐level strategies to exploit device behavior and mitigate non‐idealities, it shows pathways for building efficient, scalable, and ...
Kapil Bhardwaj   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy