Results 11 to 20 of about 89,074 (350)

EXPERIMENTAL RESEARCH ON EXTINGUISHING COMBUSTIBLE POLAR LIQUIDS. CONCEPT OF FIRE TESTS [PDF]

open access: yesАктуальные вопросы пожарной безопасности
Methods and means for extinguishing the most common flammable liquids such as diesel fuel, gasoline, etc. (water-insoluble hydrocarbons), in most cases are not effective in extinguishing fires of water-soluble polar liquids.
Dmitry V. Fedotkin   +3 more
doaj   +1 more source

Physical modeling of a fire with the use of the Froude number

open access: yesBudownictwo i Architektura, 2019
Ever since the field of Fire Safety Engineering first came into existence, small-scale (model scale) fire tests were the source of much valuable information about the phenomena occurring during combustion. Over the years, several computational methods to
Mateusz Zimny
doaj   +1 more source

Maximizing information obtained from standardized fire tests using a Bayesian framework

open access: yesActa Polytechnica CTU Proceedings, 2022
Current practice is mostly focused on prescriptive design approaches where the performance of the structure in case of fire is assessed based on its performance in standardized fire tests.
Balša Jovanović   +4 more
doaj   +1 more source

Modeling of fire exposure in facade fire testing

open access: yesFire and Materials, 2017
SummaryIn this paper, a comparative simulation study on 3 large‐scale facade testing methods, namely, the SP Fire 105, BS 8414‐1, and the ISO 13785‐2 methods, is presented. Generally good correspondence between simulations and experimental data has been found, provided that thermal properties of the facade material and heat release rates are known ...
J. Anderson   +3 more
openaire   +5 more sources

Experimental room fire studies with perforated suspended ceiling [PDF]

open access: yes, 2011
10th International Symposium on Fire Safety Science, College Park, MD, 19-24 June 2011Suspended false ceilings are commonly installed as a new interior design feature in modern buildings of the Far East.
Tsui, FSC   +10 more
core   +1 more source

Finite Element Analysis and Calculation Method of Residual Flexural Capacity of Post-fire RC Beams

open access: yesInternational Journal of Concrete Structures and Materials, 2020
Fire tests and subsequent bending tests of four reinforced concrete (RC) beams were performed. Based on these tests, the post-fire performance of RC beams was further studied using finite-element simulation through reasonable selection of suitable ...
Bin Cai, Bo Li, Feng Fu
doaj   +1 more source

How to Protect Staircases in Case of Fire in Mid-Rise Buildings. Real Scale Fire Tests

open access: yesSafety & Fire Technology, 2019
Aim: The aim of the analysis was to investigate how smoke would spread in the building in the case of fire, and how to protect staircases without a pressure differential system (PDS). It was assumed that a ventilation system should: prevent the staircase
Grzegorz Kubicki   +2 more
doaj   +1 more source

Enhancement in fire retardant Properties of Coconut Coir/Polyurethane acoustic composites

open access: yesJournal of Natural Fibers, 2022
This study aims to enhance the flammability properties of coconut coir and polyurethane resin sound-absorbing material. Sound absorption properties of the material for normal sound incidence were measured using impedance tube setup up based on ISO 10534 ...
Nirmala H. Bhingare, S. Prakash
doaj   +1 more source

An Experimental Investigation on Fire Extinguishing Powder Efficiency

open access: yesChemical Engineering Transactions, 2020
A series of large-scale tests were carried out to evaluate the effectiveness of using extinguishing powder (Purple K) to supress propane or petrol fire or to reduce emitted radiative heat flux.
Frederic Heymes   +4 more
doaj   +1 more source

Some Approaches to Developing a Test Method for Determining the Actual Fire Resistance Limit of Façade Translucent Structures [PDF]

open access: yesE3S Web of Conferences, 2021
Based on the analysis of modern construction of high-rise buildings with façade translucent structures (FTS), it was established that the actual fire resistance limit of FTS for high-rise buildings should be assessed.
Eremina Tatiana   +4 more
doaj   +1 more source