Background Screw loosening of a cement-retained, implant-supported fixed partial denture causes the abutment and restoration to be completely separated as one unit from the implant body.
Asmaa N. Elboraey+3 more
doaj +2 more sources
Structural Integrity of Anterior Ceramic Resin-Bonded Fixed Partial Denture: A Finite Element Analysis Study. [PDF]
This study was conducted as a means to evaluate the stress distribution patterns of anterior ceramic resin-bonded fixed partial dentures derived from different materials and numerous connector designs that had various loading conditions imposed onto them
Osman MLM+5 more
europepmc +2 more sources
Influence of Abutment Design on Biomechanical Behavior to Support a Screw-Retained 3-Unit Fixed Partial Denture. [PDF]
This study aimed to evaluate the biomechanical behavior of Morse taper implants using different abutments (CMN abutment [(CMN Group] and miniconical abutments [MC Group]), indicated to support a screw-retained 3-unit fixed partial denture.
Lopes GDRS+9 more
europepmc +2 more sources
Three-Dimensional Finite Element Analysis of the Veneer—Framework Thickness in an All-Ceramic Implant Supported Fixed Partial Denture [PDF]
This study was performed as an adjunct to an existing clinical study to validate the effect of veneer: framework thickness ratio on stress distribution in an implant-supported all-ceramic fixed partial denture.
Lohitha Kalluri+4 more
openalex +2 more sources
Fracture Load of Metal, Zirconia and Polyetheretherketone Posterior CAD-CAM Milled Fixed Partial Denture Frameworks. [PDF]
The aim of this study was to investigate the load to fracture and fracture pattern of prosthetic frameworks for tooth-supported fixed partial dentures (FPDs) fabricated with different subtractive computer-aided design and computer-aided manufacturing ...
Rodríguez V+4 more
europepmc +2 more sources
Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems. [PDF]
Background: CAD/CAM systems enable the production of fixed partial dentures with small and reproducible internal and marginal gaps. Purpose: The purpose of this study was to evaluate the reproducibility of the marginal and internal adaptations of four ...
Lehmann KM+7 more
europepmc +2 more sources
Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study. [PDF]
PURPOSE To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion.
Acharya PH+3 more
europepmc +2 more sources
Evaluation of Complications Associated with Fixed Partial Denture: A Prospective Study.
Objective: To assess complications, survival rates, and patient-reported outcomes associated with fixed partial dentures (FPDs). Methods: A cohort of 146 subjects, aged 18 and above, requiring FPD were recruited.
Karthikeyan B+6 more
europepmc +2 more sources
BACKGROUND Accuracy of intraoral implant scans may be affected by the region of the implant and the type of the intraoral scanner (IOSs). However, there is limited knowledge on the scan accuracy of multiple implants placed for an implant-supported fixed ...
M. B. Donmez+5 more
semanticscholar +1 more source