Results 251 to 260 of about 51,336 (317)
Some of the next articles are maybe not open access.

Effect of Different Preparation Depths for an Inlay-Retained Fixed Partial Denture on the Accuracy of Different Intraoral Scanners: An In Vitro Study.

Journal of Prosthodontics, 2021
PURPOSE The aim was to evaluate the effect of different preparation depths for inlay-retained fixed partial dentures on the accuracy of intraoral scanners. MATERIALS AND METHODS Tooth preparations for two inlay-retained fixed partial dentures were done
M. Khaled, A. Sabet, K. Ebeid, T. Salah
semanticscholar   +1 more source

A Comparative Study of the Accuracy of Dental CAD Programs in Designing a Fixed Partial Denture.

Journal of Prosthodontics, 2021
PURPOSE Error testing at each stage of prosthetic manufacturing remains relatively underdeveloped for computer-aided design/computer-aided manufacturing methods, and no experimental studies have validated the computer-aided design programs.
Yong-Sang Lee   +3 more
semanticscholar   +1 more source

Influence of Digital Technologies and Framework Design on the Load to Fracture of Co-Cr Posterior Fixed Partial Denture Frameworks.

Journal of Prosthodontics, 2021
PURPOSE To compare the load to fracture of cobalt-chromium 3-unit posterior fixed partial denture frameworks manufactured by conventional and digital techniques and to evaluate the influence of the framework design on the fracture load.
Celia Tobar   +4 more
semanticscholar   +1 more source

Fixed-removable partial denture

The Journal of Prosthetic Dentistry, 1982
Abstract The technique and rationale have been presented for the fixed-removable partial denture. This type of denture has qualities of both the fixed partial denture and the removable partial denture and is indicated where the abutments would support a fixed partial denture but a severe defect is present in the edentulous space.
Leonard A. Mueninghoff, Mark Johnson
openaire   +3 more sources

Longevity of fixed partial dentures

The Journal of Prosthetic Dentistry, 1997
The anticipated length of service and reasons for replacement of fixed partial dentures (FPDs) are a frequent inquiry by patients. Previous reports have provided limited information on material and techniques used in restoration or standards in evaluations of restorations at delivery.This study determined the reasons for failure and length of service ...
William E. LaVelle   +3 more
openaire   +3 more sources

Immediate fixed partial dentures

The Journal of Prosthetic Dentistry, 1988
This technique offers immediate fixed partial denture replacement of dentition lost in either an anterior or posterior location. It allows modification of the preextraction tooth or the diagnostic wax-up. Because the provisional restoration is made indirectly, the extraction site is not contaminated.
James M. Leary   +2 more
openaire   +3 more sources

Fixed partial dentures opposing complete dentures

The Journal of Prosthetic Dentistry, 1989
When fixed partial dentures are indicated in an arch opposing a complete denture, it is best to develop the occlusal surfaces of the fixed restorations at the same time that the opposing denture teeth are arranged in wax to permit greater flexibility and reduce the compromise in developing bilateral balanced occlusion.
Kevin C. White   +2 more
openaire   +3 more sources

Removal of partially loosened fixed partial dentures

The Journal of Prosthetic Dentistry, 1981
The technique described offers maximum safety for the abutment tooth and the probability of salvage of the existing restoration. The options of reusing the restoration or recementing it as a temporary restoration are both attractive.
Daniel L. Hall, Robert J. Connor
openaire   +3 more sources

Nonrigid Connectors for Fixed Partial Dentures [PDF]

open access: possibleThe Journal of the American Dental Association, 1973
Because of physiologic tooth movement, arch position of the abutments, and the retentive capacity of the retainers, a nonrigid connector may be preferred in the fabrication of a five-unit pier-abutment fixed partial denture. In this prosthesis, the movement of the nonrigid connector is enough to prevent the middle abutment from serving as a fulcrum ...
Donald W. Fisher   +1 more
openaire   +2 more sources

Effect of supporting implants inclination on stability of fixed partial denture: A finite element study

Proceedings of the Institution of mechanical engineers. Part H, journal of engineering in medicine, 2020
The aim of this finite element study was to analyze effect of supporting implants inclination on stress distribution in the bone for a four-unit fixed partial denture.
Amel Boukhlif   +7 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy