Results 31 to 40 of about 19,873 (264)
Influence of Mountain Wildfires on the Insulation Properties of Air Gaps in Power Grids
The complex terrain of China frequently leads to wildfires, which in turn pose a threat to the safe operation of power transmission lines. Studying the breakdown characteristics of air gaps under wildfire conditions is of great significance for ...
Fangrong Zhou +8 more
doaj +1 more source
Effect of Equivalence Ratio on Flame Morphology, Thermal and Emissions Characteristics of Inverse Diffusion Porous Burner [PDF]
The diffusion porous media combustion is one possible way to eliminate the drawbacks of the existing combustion systems. Inverse diffusion flame (IDF) has features of both premixed and non-premixed flames.
A. Dekhatawala, P. V. Bhale, R. Shah
doaj +1 more source
This study investigates the possibility of substituting liquid petroleum gas (LPG) with dimethyl ether (DME) by considering the procedures of burner design in terms of working region, flame stability, and flame height. An experiment was designed using
Riesta Anggarani +4 more
doaj +1 more source
Flame merging of line fires is very complex with the interaction of fire dynamics and fluid flow et al., which will often generate different burning behaviors.
Xinjie Huang +7 more
doaj +1 more source
Effect of Nozzle Height on the Combustion Dynamics of Jet Fires in Rotating Flow Fields
In this paper, the effect of nozzle height on the combustion dynamics of jet fires in rotating flow fields (JFRFFs) is systematically investigated through experimental and numerical simulations.
Qiang Zhang +7 more
doaj +1 more source
An experimental study on coflow diffusion combustion in a pellet-packed bed with different bed lengths [PDF]
In experimental investigations on axial symmetry, over-ventilated CH4/air diffusion combustion in a packed bed is executed to study the height, shape and stability of the flame.
Junrui Shi +6 more
doaj +1 more source
In this paper, a series of burning experiments with the downward fire spread were carried out using 1 mm thick, 200 mm tall PMMA with different widths varying from 50 mm to 150 mm in 13 mm restricted distance.
Shuai Gao +3 more
doaj +1 more source
Fire safety of utility tunnel, which is significantly affected with cables, has arouse public concern. This work experimentally investigated influences of interlayer distance (d) and cable spacing (s) on flame characteristics and fire hazard of ...
Weiguang An +4 more
doaj +1 more source
Coagulative granular hydrogels are composed of packed thrombin‐functionalized microgels that catalyze the conversion of fibrinogen into a secondary fibrin network, filling the interstitial voids. This bio‐inspired approach stabilizes the biomaterial to match the robustness of bulk hydrogels without compromising injectability, mimicking the initial ...
Zhipeng Deng +16 more
wiley +1 more source
Flame projection lengths of horizontally oriented buoyant jet fires under different air pressures
A horizontal buoyancy-controlled jet fire forms when a gaseous fuel leakage occurs in a pipe or a fuel tank and the fuel is ignited. In this study, the horizontal flame projection length (Lph) from such fires was experimentally investigated under ...
Jinfei Zhao +3 more
doaj +1 more source