Results 221 to 230 of about 5,541 (264)
Some of the next articles are maybe not open access.

Flat Slab and Waffle Slab Systems

1994
The effects of column grid size, number of storeys, use of mild/high yield steel reinforcement, location of structural element, grade of concrete and provision of column heads in structural systems on the quantities of various constituents of reinforced concrete construction using flat slabs and waffle slabs have been studied and presented in the form ...
openaire   +1 more source

The Advanced Theory of Flat Slabs

ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik, 1966
AbstractIn a preceding paper the author dealt with the bending moments in a uniformly loaded flat slab supported by columns with circular sections. In this paper the shearing forces in the flat slab, its deflection and the slopes of the deflection surface are expressed by the functions which are deduced from the Theta functions.
openaire   +2 more sources

Voided "Two-Way" Flat Slabs

Structures Congress 2013, 2013
Voided slabs have been used in construction of reinforced concrete floor systems for over 100 years. This article offers an historical perspective on this technology. A discussion of early applications thru several case studies is followed by on overview of traditional systems still in use and concludes with a discussion on new technological ...
openaire   +1 more source

Serviceability uncertainties in flat slabs

Structural Concrete, 2014
AbstractService load tests on the 6th floor of the full‐scale reinforced concrete building at BRE Cardington are described. Both deflections and reinforcement strains were measured. Finite element analyses of the floor slab were then undertaken using the measured material properties and four different models for the behaviour of the concrete in tension,
openaire   +1 more source

Earthquake Response of Flat‐Slab Buildings

Journal of Structural Engineering, 1994
System identification, three-dimensional linear dynamic analysis, and code-specified conventional equivalent static techniques are used to evaluate the response of a nine-story flat-slab building during the Loma Prieta Calif., earthquake of 1989. Four different models are used in the finite-element–based dynamic and static analyses.
Ahmad J. Durrani   +3 more
openaire   +1 more source

Slab STRESS – Seismic Testing of a R/C Flat Slab Structure

2019
A research entitled Slab STRESS - Slab STructuralRESponse for European Seismic Design, within the European project SERA - H2020-INFRAIA-2016-1, is currently in progress to study the response of flat slab floors under combined gravity and lateral loads.
D. Coronelli, P. Bamonte
openaire   +2 more sources

Membrane Analysis of Flat Plate Slabs

ACI Structural Journal, 1989
Tests of 47 one-way reinforced concrete slab strips subjected to uniformly distributed loads are reported. The slabs are typical of those used in the flat-plate designs of protective construction. An analytical procedure modified from previous investigations is used as basis for determining the peak flexural capacity of slabs.
openaire   +1 more source

Tunable structured light with flat optics

Science, 2022
Ahmed H Dorrah, Federico Capasso
exaly  

Flat slabs

2017
Charles E. Reynolds, James C. Steedman
openaire   +1 more source

Home - About - Disclaimer - Privacy