Results 121 to 130 of about 1,131,199 (228)

Architected Bio‐Based Iontronic Skin With Dual‐Mode Pressure and Strain Sensing

open access: yesAdvanced Functional Materials, EarlyView.
Bio‐based acrylates in combination with an ionic liquid create 3D‐printed ionogels with compositionally tuneable mechanics and ionic conductivity. Gyroid architectures amplify low‐pressure sensitivity while preserving robust strain sensing, enabling dual‐mode detection of pressure and deformation.
Maksims Jurinovs   +8 more
wiley   +1 more source

Highly Efficient and Stable Roll‐to‐Roll Coated Perovskite Solar Cells Enabled by Antisolvent Vapor‐Assisted Crystallization

open access: yesAdvanced Functional Materials, EarlyView.
Antisolvent Vapour‐Assisted Crystallization (AVAC) enables controlled perovskite crystallization through precisely metered antisolvent vapour, eliminating liquid antisolvent waste. Compatible with roll‐to‐roll (R2R) slot‐die coating, AVAC produces uniform, pinhole‐free films with enlarged grains, delivering efficiencies of 18.3% for R2R fabricated ...
Narendra Pai   +11 more
wiley   +1 more source

Biodegradable Conductors for Implantable and Wearable Transient Bioelectronics

open access: yesAdvanced Functional Materials, EarlyView.
Biodegradable conductors are essential building blocks for transient bioelectronics, enabling temporary sensing, stimulation, and energy transfer while eliminating the need for device retrieval. This review summarizes biodegradable metals, conducting polymers, ionic conductors, and conductive composites, highlighting degradation mechanisms, material ...
Yicheng Zhu, Yijun Liu, Naoji Matsuhisa
wiley   +1 more source

Engineering Intraframework Energy Transfer in Metal‐Organic Frameworks for Luminescent Discrimination of Bisphenol Pollutants

open access: yesAdvanced Functional Materials, EarlyView.
A family of isostructural lanthanide metal–organic frameworks serves as a model platform to disentangle metal‐to‐metal and linker‐to‐linker energy transfer during luminescence sensing. The results reveal that rigid lanthanide energy migration governs sensing performance, whereas linker‐mediated pathways exert only minor effects, providing mechanistic ...
Zongsu Han   +4 more
wiley   +1 more source

Photochromic Artificial Synapses for Neuromorphic Electronics: Mechanisms, Device Architectures, and Emerging Applications

open access: yesAdvanced Functional Materials, EarlyView.
Photochromic materials offer a promising route toward light‐programmable neuromorphic electronics through reversible, multilevel, and nonvolatile state modulation. This review establishes links between photochromic switching mechanisms, device architectures, and neuromorphic functions, spanning diverse materials and platforms.
Debdatta Panigrahi   +6 more
wiley   +1 more source

NeuroVisio SyncPatch: A Skin‐Conformal Multimodal EMG–Motion Sensing Platform for Quantitative Neuromuscular Rehabilitation and Performance Monitoring

open access: yesAdvanced Healthcare Materials, EarlyView.
NeuroVisio SyncPatch integrates skin‐conformal electromyography (EMG) electrodes with camera‐tracked markers to jointly assess muscle activity and three‐dimensional knee kinematics during rehabilitation. Parallel feedback pathways provide real‐time kinematic guidance during movement and post‐trial neuromuscular feedback.
Bohyung Choi   +11 more
wiley   +1 more source

Biocompatible Conjugated Electrospinning Nanofibrous Membrane With Self‐Powered Piezoelectric Capacity for Accelerated Wound Healing

open access: yesAdvanced Healthcare Materials, EarlyView.
A self‐powered PCL/gelatin‐PVDF‐TrFE/MXene conjugated electrospun membrane integrates biocompatibility with enhanced piezoelectric responsiveness. Mechanical deformation is converted into localized electrical signals that stimulate wound‐repair cells proliferation and migration, promote angiogenesis and tissue remodeling, and accelerate full‐thickness ...
Diandian Li   +11 more
wiley   +1 more source

A Wearable Microfluidic Sweat‐Patch Pilot Study for Detecting Breast‐Cancer Proteins CEA and PIP/GCDFP‐15

open access: yesAdvanced Healthcare Materials, EarlyView.
A passive capillary‐driven microfluidic patch standardizes noninvasive sweat collection from the axilla and chest during exercise. Paired sweat and capillary blood samples enable laboratory ELISA analysis of CEA and PIP. CEA is detectable but often below quantification limits, while PIP remains undetectable in sweat.
Fatemeh Esmaeildoost   +7 more
wiley   +1 more source

Single‐Chromophore Homojunction Organic Solar Cells: A Path to Simplicity and Efficiency

open access: yesAdvanced Materials, EarlyView.
This perspective discusses how the intrinsic optoelectronic properties of organic semiconductors, their molecular packing in the solid‐state, and internal energetic gradients within a device can enable free‐charge carrier generation in homojunction organic solar cells.
Shaun McAnally   +2 more
wiley   +1 more source

Self‐Assembled Monolayers in p–i–n Perovskite Solar Cells: Molecular Design, Interfacial Engineering, and Machine Learning–Accelerated Material Discovery

open access: yesAdvanced Materials, EarlyView.
This review highlights the role of self‐assembled monolayers (SAMs) in perovskite solar cells, covering molecular engineering, multifunctional interface regulation, machine learning (ML) accelerated discovery, advanced device architectures, and pathways toward scalable fabrication and commercialization for high‐efficiency and stable single‐junction and
Asmat Ullah, Ying Luo, Stefaan De Wolf
wiley   +1 more source

Home - About - Disclaimer - Privacy