Results 91 to 100 of about 4,217 (207)
Multifunctional Flexible Thermoelectric Fabric for Smart Wearables
This study designs a multifunctional rGO/PEDOT:PSS fabric integrating thermoelectric generation, signal sensing, and EMI shielding. It enables motion detection, respiratory monitoring, and fetal movement tracking. The fabric emphasizes flexibility, durability, comfort, and safety, making it suitable for wearable healthcare applications and advancing ...
Jia Wu +10 more
wiley +1 more source
To investigate the influence of external prestressing with carbon fiber-reinforced polymer (CFRP) tendons on the flexural and shear performance of reinforced concrete beams, a total of six simply supported beams with a length of 3.5 m and two two-span ...
Zhuang Wang +3 more
doaj +1 more source
ABSTRACT Post‐translational modifications (PTMs) to tubulin subunits in microtubule filaments are thought to comprise a component of the tubulin code that specifies microtubule functions in cell physiology and animal development. Acetylation of Lysine‐40 (K40) on α‐tubulin (αTub‐K40ac) and glutamylation of both α‐ and β‐tubulin are two tubulin PTMs of ...
Lynne Blasius +6 more
wiley +1 more source
Review and prospects of shear test of bolted rock joints
The laboratory shear test equipment, test method, and numerical simulation of bolted rock joints were summarized. The shortcomings and limitations of the current research were analyzed, and the research prospects were proposed. Abstract Rock bolting is a critical approach in geotechnical engineering for supporting weak rocks.
Shulin Ren +4 more
wiley +1 more source
HIRAMATSU, Yoshio +3 more
openaire +2 more sources
Flexible Direct‐Conversion X‐Ray Detectors: From Emerging Materials to Conformal Imaging
This comprehensive review analyzed the performance, challenges, and future directions of four emerging material systems for next‐generation flexible direct‐conversion X‐ray detectors: organic semiconductors, perovskites, metal–organic frameworks, and inorganic metal compounds.
Haipeng Di +11 more
wiley +1 more source
False failure in flexural fatigue tests
Flexural fatigue tests are typically run under displacement or in a straincontrolled mode. In these tests, either the oscillatory displacement amplitude or strain amplitude applied to the bottom of the specimen is kept constant. The evolution of loading required to cause fatigue is then measured.
Pérez Jiménez, Félix Edmundo +5 more
openaire +1 more source
A sprayable POE‐based sorbent formulated with a green solvent blend of α‐pinene, D‐limonene, and p‐cymene enables rapid in situ film formation via solvent evaporation, allowing efficient pollutant capture. The system exhibits high oil uptake (37.3 g g−1) and effectively removes up to 60 mL of VLSFO under simulated marine spill conditions.
Youngmin Choi, Changwoo Nam
wiley +1 more source
Comparison of the flexural strength of printed and milled denture base materials
Background To evaluate the flexural strength of digitally milled and printed denture base materials. Methods The materials tested were Lucitone 199 denture base disc (Dentsply Sirona), AvaDent denture base puck (AvaDent), KeyMill denture base disc ...
Shatha Alshali +3 more
doaj +1 more source
Harnessing Thin‐Film Solid‐State Electrolytes: Enabling Breakthroughs in All‐Solid‐State Batteries
Schematic illustration highlighting the advantages of transitioning from traditional thick solid‐state electrolytes (SSEs) to thin‐film SSEs. Thinning the electrolyte enables higher ionic conductivity, reduced interfacial polarization, improved flexibility, compact electrode contact, and enhanced energy density, offering a promising pathway toward high‐
Yitao He +3 more
wiley +1 more source

