Results 251 to 260 of about 50,864 (305)
Some of the next articles are maybe not open access.

Measuring pulsating gas-flows

Measurement Techniques, 1961
The above considerations show that until reliable data are available there is no point in including in the All-Union standard specification for measuring flows a recommendation for evaluating the error in measuring pulsating flows by means of the damping criterion and to classify the differential manometers combined with constricting devices among ...
S. B. Bulatov   +2 more
openaire   +1 more source

Bluff body aerodynamics in pulsating flow

Journal of Wind Engineering and Industrial Aerodynamics, 1988
Abstract The effect of pulsating flow superposed upon a mean flow on the side surface pressure fluctuations of two-dimensional (2-D) rectangular cylinders with slenderness ratios (width/height ratio, B/D) ranging from 0.5 to 20 has been studied. The purpose of this study was to understand the mechanism of interaction between external flow pulsations ...
M. Matsumoto, N. Shiraishi, H. Shirato
openaire   +1 more source

Spectral dynamic of pulsating turbulent pipe flow

Computers & Fluids, 2008
zbMATH Open Web Interface contents unavailable due to conflicting licenses.
MANNA, MARCELLO, Vacca, A.
openaire   +2 more sources

Pulsating wave propagation in reactive flows: Flow-distributed oscillations

Physical Review E, 2000
Stationary waves in a reactive flow with equal transport coefficients were recently generated by passing the oscillating Belousov-Zhabotinsky reaction medium through a tubular packed bed reactor while keeping the concentrations constant at the inflow boundary [M. Kaern and M. Menzinger, Phys. Rev. E 60, 3471 (1999)].
, Kaern, , Menzinger
openaire   +2 more sources

Pulsating Air Flow

Journal of Fluids Engineering, 1934
Abstract Mechanically induced air flow is pulsating even when it may seem steady to the physical senses. This pulsation causes errors in velocity measurement that are often as great as twenty per cent when the conventional pitot tube or orifice is used with a liquid manometer, and it causes an increase in the velocity-energy and fluid ...
openaire   +1 more source

Microfluidic mixing using pulsating flows

Microfluidics and Nanofluidics, 2016
Mixing of biological species in microfluidic channels is challenging since the mixing process is limited by the small mass diffusion coefficient of the species and by the dominance of viscous effects, captured by the low value of Reynolds number characteristic of laminar liquid flow in microchannels.
Farah Cheaib   +4 more
openaire   +1 more source

Measuring pulsating flow with ultrasound

Measurement, 2001
This paper continues the research presented at the IMEKO XV World Congress in Osaka/JP. It gives deeper insights into the topic of measuring the average volume flow with ultrasound based flow meters in a pulsating fluid. Pulsations are very common in industrial applications so that flow meters have to cope with this kind of disturbances.
Volker Skwarek   +2 more
openaire   +1 more source

HEAT TRANSFER WITH PULSATING FLOW

Chemical Engineering Communications, 1980
This report concerns the frequency dependence of the heat transfer coefficient for water flowing in a tube. The investigation of this phenomenon was conducted in a double pipe heat exchanger in which the center stream was pulsed. The frequencies used ranged from 10 to 160 cycles per minute, and the average flow rates corresponded to a Reynolds number ...
J.C. LUDLOW, D.J. KIRWAN, J.L. GAINER
openaire   +1 more source

Pulsating flow over a step

The Physics of Fluids, 1980
An experimental study has been made of air flow over a rearward facing step where the free-stream velocity has been perturbed by a sinusoidal fluctuation of 1 Hz. Velocities have been measured using a laser Doppler anemometer employing a gated photon correlation signal detection system.
T. Mullin, C. A. Greated, I. Grant
openaire   +1 more source

Pulsating slurry flow in pipelines

Experiments in Fluids, 1989
An experimental study on pulsating turbulent flow of sand-water suspension was carried out. The objective was to investigate the effect of pulsating flow parameters, such as, frequency and amplitude on the critical velocity, the pressure drop per unit length of pipeline and hence the energy requirements for hydraulic transportation of a unit mass of ...
O. A. El Masry, K. El Shobaky
openaire   +1 more source

Home - About - Disclaimer - Privacy