Results 61 to 70 of about 2,540,422 (314)

Design of Gerotor Oil Pump with 2-Expanded Cardioids Lobe Shape for Noise Reduction

open access: yesEnergies, 2019
Gerotor pump technology is being increasingly employed in innovative application fields, such as engines and as the hydraulic source of automatic transmissions.
Sang Hyeop Lee   +3 more
doaj   +1 more source

Experience With Performing Rheocarna Therapy via the Single‐Needle Method for Treatment of Chronic Limb‐Threatening Ischemia

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction This study investigated the safety and efficacy of single‐needle Rheocarna therapy for chronic limb‐threatening ischemia (CLTI) with wounds. Methods Six patients with CLTI involving ulcers unresponsive to revascularization underwent single‐needle Rheocarna treatment.
Yasutaka Yamauchi   +9 more
wiley   +1 more source

Effectiveness of a Novel Low‐Density Lipoprotein Apheresis Device Rheocarna in Patients Undergoing Hemodialysis With Chronic Limb‐Threatening Ischemia: A Single‐Center Retrospective Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Chronic limb‐threatening ischemia (CLTI) is a severe form of lower‐extremity artery disease characterized by distal lesions and microcirculatory impairment, limiting revascularization efficacy. Rheocarna is a direct hemoperfusion low‐density lipoprotein (LDL) adsorption device with potential rheological and anti‐inflammatory ...
Kunihiro Ishioka   +12 more
wiley   +1 more source

Prognosis of Long‐Term Continuous Renal Replacement Therapy and the Impact of Combined Continuous Intravenous Sodium Infusion Therapy

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Patients requiring long‐term continuous renal replacement therapy (CRRT) generally have poor prognoses. This study evaluated whether adding continuous intravenous sodium infusion (cIVNa) is associated with improved hemodynamics and outcomes in patients undergoing long‐term CRRT for ≥ 7 days.
Akinori Yamaguchi   +6 more
wiley   +1 more source

Establishing an Apheresis Medicine Program in a Resource‐Constrained Setting: A 5‐Year Experience From Lagos, Nigeria

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Establishing a comprehensive apheresis medicine program in a resource‐constrained setting presents significant structural, financial, and logistical challenges. Despite the growing clinical importance of apheresis services globally, published experience from sub‐Saharan Africa remains sparse.
Folasade Adelekan‐Popoola   +4 more
wiley   +1 more source

Angular Rate Sensing by Circulatory Vortex Flow: Design, Simulation and Experiment

open access: yes, 2019
A fully packaged convective vortex gyrometer actuated by a PZT diaphragm is reported. The flow circulates at higher velocity after each actuating circle to form a vortex in the desired chamber. The vortex is characterized by hotwire anemometry.
Bui, Thanh Bui   +13 more
core   +1 more source

Evolution of Turbulent Swirling Flow in a Small-Scale Cyclone with Increasing Flow Rate : A LES Study

open access: yes, 2021
The flow field, vortex behaviour and pressure losses in a small-scale cyclone have been studied at a wide range of flow rate 0.23-39.7 NLPM (measured at 1 atm and 20 degrees C) using the LES simulations that have been validated based on experimental ...
Lidén, Göran,   +2 more
core   +1 more source

Comparative Evaluation of Hemodiafiltration, Hemoperfusion, and Standard Hemodialysis on Efficacy, Inflammatory Control, Dialysis Adequacy, and Safety in End‐Stage Renal Disease: A Prospective Observational Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Chronic micro‐inflammation in patients with end‐stage renal disease (ESRD) is a significant driver of cardiovascular complications and diminished quality of life. While standard hemodialysis (SHD) effectively manages small‐molecule clearance, its ability to remove medium‐to‐large uremic toxins—the primary catalysts of systemic ...
Hongwei Zuo   +5 more
wiley   +1 more source

Analysis of Flow Meters Calibration [PDF]

open access: yes, 2015
Calibration data of flow meters are often reported using the so called calibration coefficient, i.e. the ratio between the reference flow rate (or equivalent quantity, e.g.
SPAZZINI, PIER GIORGIO   +3 more
core  

Order Flow and Exchange Rate Dynamics [PDF]

open access: yes
Macroeconomic models of nominal exchange rates perform poorly. In sample, R2 statistics as high as 10 percent are rare. Out of sample, these models are typically out-forecast by a na‹ve random walk. This paper presents a model of a new kind.
Richard K. Lyons, Martin D.D. Evans
core   +2 more sources

Home - About - Disclaimer - Privacy