Prototype of the particle fluence measurement device [PDF]

open access: yesNuclear Technology and Radiation Protection, 2012
A method of measuring particle fluence and ion beam current in experiments of ion implantation is presented. The design and technical details of a realized prototype device are discussed.
Trajić Ivan M.   +5 more
doaj   +3 more sources

Comparing efficacy of reduced-fluence and standard-fluence photodynamic therapy in the treatment of polypoidal choroidal vasculopathy [PDF]

open access: yesBMC Ophthalmology, 2020
Background The EVEREST II study reported superior polyp closure rates and visual outcomes using combination standard photodynamic therapy (PDT) with intravitreal ranibizumab in the treatment of polypoidal choroidal vasculopathy (PCV).
Wei Kiong Ngo   +3 more
doaj   +3 more sources

Methodology for an experimental drift velocity determination using a μTPC. Example in a 700mbar 95%He+5%CO2 mixture [PDF]

open access: yesEPJ Web of Conferences, 2023
The micro-irradiation, neutron metrology and dosimetry laboratory of the Institute for Radiological Protection and Nuclear Safety (IRSN) is a National Metrological Institute associated laboratory, is in charge of the neutron fluence distribution ...
Vinchon Thibaut, Petit Michaël
doaj   +1 more source

Comparative results of micropulse transscleral cyclophotocoagulation considering different energy levels in patients with primary open-angle glaucoma

open access: yesОфтальмохирургия, 2023
Purpose. To evaluate the safety and efficacy of different laser energy parameters when performing micropulse transscleral cyclophotocoagulation (MP-TSCPC) in patients with different stages of primary open-angle glaucoma (POAG). Material and methods.
I.E. Ioshin   +3 more
doaj   +1 more source

Verification of Radiation Fluence using Stack Film in HDR Brachytherapy with Heterogeneity Algorithm [PDF]

open access: yesJournal of Clinical and Diagnostic Research, 2018
Introduction: It is essential that Quality Assurance (QA) need to be in line with progresses in HDR brachytherapy treatment planning and delivery to ensure an appropriate level of dosimetric accuracy and quality.
Mourougan Sinnatamby   +5 more
doaj   +1 more source

X-Ray Beam Segment Size and Entrance Location Effects on the Integral Quality Monitor (IQM®) Signal and Usefulness in Predicting Complex Segment Output Signals [PDF]

open access: yesJournal of Biomedical Physics and Engineering, 2020
Background: The Integral Quality Monitor (IQM®) is an independent online dosimetry device attached to the treatment machine to monitor the accuracy of radiation delivery.
C Mahuvava, F C P Du Plessis
doaj   +1 more source

Does fluence smoothing reduce the complexity of the intensity-modulated radiation therapy treatment plan? A dosimetric analysis

open access: yesJournal of Medical Physics, 2022
Background: Intensity-modulated radiation therapy (IMRT) may have too many peaks and valleys, making the treatment plan undeliverable. When there are too many fluency differences between adjacent pixels in the X or Y directions, the X and Y smoothing ...
Dinesh Kumar Saroj   +2 more
doaj   +1 more source

Touching and being touched: where knowing and feeling meet

open access: yesFrontiers in Psychology, 2023
Philosophers maintain that touch confers a sense of reality or grounding to perceptual experience. In touching oneself, one is simultaneously both subject and object of touch, a template for experiencing oneself as subject and object of intentions ...
Lawrence Fischman, Lawrence Fischman
doaj   +1 more source

Evaluation of the Minority-Carrier Lifetime of IMM3J Solar Cells under Proton Irradiation Based on Electroluminescence

open access: yesCrystals, 2023
The shortening of the minority carrier lifetime is the main reason for the degradation of the electrical performance of solar cells; therefore, it is particularly important to evaluate the minority carrier lifetime of inverted metamorphic triple junction
Jing Xu, Gang Yan, Ming Lu
doaj   +1 more source

Verification of TG-61 dose for synchrotron-produced monochromatic x-ray beams using fluence-normalized MCNP5 calculations [PDF]

open access: yes, 2012
Ion chamber dosimetry is being used to calibrate dose for cell irradiations designed to investigate photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility.
Alvarez, Diane   +4 more