Results 11 to 20 of about 463,363 (141)

Surgical Management of Arterial Thoracic Outlet Syndrome due to Cervical Rib in a 17-Year-Old Male With Gangrenous Ulcer on Fingertip Requiring Multiple Bypass: A Case Report. [PDF]

open access: yesClin Case Rep
ABSTRACT Arterial thoracic outlet syndrome (ATOS) is a rare condition, affecting 1% to 5% of TOS cases, characterized by the compression of the subclavian artery, often due to anatomical anomalies like cervical ribs. Cervical ribs that are not a very common anatomical anomaly can give rise to arterial supply compromise needing surgical intervention to ...
Babar I   +6 more
europepmc   +2 more sources

Use of Fogarty catheter as bronchial blocker for lung isolation in children undergoing thoracic surgery: A single centre experience of 15 cases

open access: yesAnnals of Cardiac Anaesthesia, 2022
Background and Aim: Various devices such as single lumen tubes, balloon-tipped bronchial blockers, and double-lumen tubes can be used for lung isolation in children, but no particular device is ideal.
B. Behera   +3 more
semanticscholar   +1 more source

Insertion of a Fogarty catheter through a slip joint section for neonatal and infantile one-lung ventilation : a report of two cases.

open access: yesJournal of Medical Investigation, 2021
Here, we report two cases involving a neonate and child in which a slip joint section was used to thread a Fogarty catheter into the endotracheal tube for one-lung ventilation (OLV). Both the neonate and infant required OLV, and were placed under general
H. Yonezawa   +6 more
semanticscholar   +1 more source

Iatrogenic tibial arteriovenous fistula after Fogarty balloon catheter graft thrombectomy

open access: yesClinical Case Reports, 2021
A 75‐year‐old male presented with an immediately threatened grade IIb acute ischemia of the left leg due to thrombosis of a femoro‐infrapopliteal prosthetic bypass graft.
S. Papadoulas   +8 more
semanticscholar   +1 more source

Damage From the Fogarty Balloon Catheter

open access: yesJournal of British Surgery, 1972
Abstract The Fogarty balloon catheter is an instrument which greatly facilitates arterial thrombo-embolectomy. However, it should be used with gentleness and care, particularly in relation to the lower leg vessels. The peroneal artery is particularly susceptible to damage, and arteriovenous fistula formation may result.
G E, Mavor   +3 more
openaire   +2 more sources

Authors’ reply: Anesthetic management of a patient with montgomery t-tube in-situ for direct laryngoscopy

open access: yesJournal of Anaesthesiology Clinical Pharmacology, 2013
Another method we have successfully used is the insertion of a small appropriate sized endotracheal tube, either 4 or 4.5 mm ID, through the extraluminal limb into the tracheal end of the intraluminal limb [Figures 1 and 2].
Sukhyanti Kerai   +3 more
semanticscholar   +1 more source

Clinical application for DSA combined with a double-chamber Fogarty catheter in the treatment of venous crisis

open access: yesWideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques, 2020
Introduction Venous crisis, as a common vascular crisis post limb replantation, is usually treated with surgical exploration. Aim To investigate effects of digital subtraction angiography (DSA) combined with double-chamber Fogarty balloon catheter on ...
Xiaodong Li   +6 more
semanticscholar   +1 more source

Successful thrombolysis of renal allograft venous thrombosis – A case report

open access: yes, 2014
Renal allograft venous thrombosis is a rare but catastrophic complication resulting in graft failure. A 55-year-old male underwent live related renal transplantation. Donor's right kidney was placed in recipient's left iliac fossa. Graft renal artery was
S. Krishnaswamy   +2 more
semanticscholar   +1 more source

Betwixt playing the waiting game and waiting in vain: Temporal governance and the thin alignment of care under universal health coverage in Kenya

open access: yesMedical Anthropology Quarterly, EarlyView.
Abstract This article investigates how Kenyan citizens access healthcare within the framework of Universal Health Coverage (UHC) reforms. Based on ethnographic fieldwork, it reconceptualizes waiting as a politically structured phenomenon rather than a simple delay. The analysis shows that UHC reforms do not eliminate waiting but instead redistribute it,
Edwin Ambani Ameso
wiley   +1 more source

Women in space: A review of known physiological adaptations and health perspectives

open access: yesExperimental Physiology, EarlyView.
Abstract Exposure to the spaceflight environment causes adaptations in most human physiological systems, many of which are thought to affect women differently from men. Since only 11.5% of astronauts worldwide have been female, these issues are largely understudied.
Millie Hughes‐Fulford   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy