Results 241 to 250 of about 174,199 (337)

Dosimetric evaluation and clinical application of collimated apertures with proton beam line scanning in stereotactic radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Stereotactic radiotherapy (SRT) is a highly effective treatment with precision for small, localized lesions. Proton therapy, characterized by the Bragg peak, offers superior dose conformity compared to photon‐based approaches. However, challenges remain in minimizing lateral penumbra and optimizing dose delivery, particularly for small
Chen‐Yu Chou   +3 more
wiley   +1 more source

Radiotherapy medical physics in the Philippines: A contemporary overview

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose With cancer ranking as the third leading cause of death in the Philippines and a disparity in healthcare resources across regions, this research aimed to assess the state of radiotherapy medical physics in the country. Methodology The study utilized a comprehensive online survey with 94 structured questions answered by 19 clinics ...
John Paul C. Cabahug   +4 more
wiley   +1 more source

Localization accuracy of 6‐second CBCT for lung IGRT with various breathing patterns

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The 6‐second cone beam computed tomography (CBCT) acquisition of the Ethos HyperSight (Varian Medical Systems, Inc. Palo Alto, CA, USA) on‐board imaging system offers benefits, but could be too fast to accurately capture an average target position in a free‐breathing lung cancer patient. This study aimed to ascertain whether a 6‐second
Jihye Koo   +5 more
wiley   +1 more source

Comprehensive end‐to‐end dosimetry audit for stereotactic body radiotherapy in spine, lung, and soft tissue

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To create and conduct a comprehensive onsite end‐to‐end dosimetry audit to assess treatment accuracy of spine, lung, and soft tissue Stereotactic Body Radiotherapy (SBRT) across Australian and New Zealand (ANZ) radiotherapy centers. Methods The Australian Clinical Dosimetry Service (ACDS) anthropomorphic thorax phantom underwent a CT ...
Maddison Shaw   +8 more
wiley   +1 more source

Impact of respiratory motion on dose distribution in SIB‐SBRT for lung cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Respiratory motion is a major source of dose uncertainty in lung cancer radiotherapy. The dose distribution of simultaneous integrated boost‐stereotactic body radiotherapy (SIB‐SBRT) is inhomogeneous and is significantly impacted by respiratory motion for lung cancer. The effect of respiratory motion on SIB‐SBRT was investigated with a
Lingling Liu   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy