Results 181 to 190 of about 3,129,995 (305)
Beyond the Single Molecule: Multiplexed Methods in Force Spectroscopy. [PDF]
Halvorsen K, Ward A, Wong WP.
europepmc +1 more source
Ensemble Force Spectroscopy of a G-Quadruplex Cluster on a Single-Molecule Platform. [PDF]
Pokhrel P +5 more
europepmc +1 more source
In MOCVD MoS2 memristors, a current compliance‐regulated Ag filament mechanism is revealed. The filament ruptures spontaneously during volatile switching, while subsequent growth proceeds vertically through the MoS2 layers and then laterally along the van der Waals gaps during nonvolatile switching.
Yuan Fa +19 more
wiley +1 more source
The quarterly newsletter, The Ninth Flyer, published by the Ninth Air Force Association, Inc.
9th Air Force Association
core
Single-molecule insights into SAM-I riboswitch ligand binding using scaled magnetic force spectroscopy with comparison to conventional biophysical methods. [PDF]
Wang Z +9 more
europepmc +1 more source
Integration of Low‐Voltage Nanoscale MoS2 Memristors on CMOS Microchips
This article presents the first monolithic integration of nanoscale MoS2‐based memristors into the back‐end‐of‐line of foundry‐fabricated CMOS microchips in a one‐transistor‐one‐resistor (1T1R) architecture. The MoS2‐based 1T1R cells exhibit forming‐free, nonvolatile resistive switching with ultra‐low operating voltages, low cycle‐to‐cycle variability ...
Jimin Lee +16 more
wiley +1 more source
Hybridization Kinetics of miR-155 on Gold Surfaces as Investigated by Surface Plasmon Resonance and Atomic Force Spectroscopy. [PDF]
Botti V +3 more
europepmc +1 more source
Nanoindentation based on force spectroscopy with an atomic force
Se presenta una implementación del método para el sangrado de superficie basado en Microscopía de Fuerza Atómica (AFM). La implementación se realizó utilizando la espectroscopía de fuerza (FS) generalmente habilitada en estos instrumentos que permiten el movimiento vertical de la punta AFM sin desplazamiento lateral.
openaire +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
Protein force spectroscopy using magnetic tweezers: Slow and steady wins the race? [PDF]
Pritzl SD, Lipfert J.
europepmc +1 more source

