Results 181 to 190 of about 17,486 (265)

Si‐Doped Nanocrystalline Diamond as Highly Sensitive Luminescence Thermometer for the Physiological Temperature Range

open access: yesAdvanced Functional Materials, EarlyView.
In this work, diamonds with negative charged silicon‐vacancy (SiV−) centers have been designed for use as thermometers in biomedical applications. Multiparametric analysis of the emission characteristics of the SiV− centers provides extraordinary sensitivity for temperature detection in the physiological temperature range.
María Gragera   +6 more
wiley   +1 more source

Strong Lead‐Free Bioinspired Piezoceramics for Durable Energy Transducers

open access: yesAdvanced Functional Materials, EarlyView.
We fabricated brick‐and‐mortar lead‐free piezoceramics with Bi0.5Na0.5TiO3 monocrystal platelets as bricks and amorphous silica as mortar. The alignment of the bricks and the presence of the amorphous silica led to anisotropic residual stresses. These residual stresses increase the samples toughness, strength and durability while the brick alignment ...
Ruxue Yang   +12 more
wiley   +1 more source

Structural Power Composites Based on High Mass Loading Zn‐Ion Hybrid Supercapacitors with Metal Mesh Current Collectors and Aramid Nanofiber/Glass Fiber Composite Electrolytes

open access: yesAdvanced Functional Materials, EarlyView.
A multifunctional structural power composite is developed by integrating high‐mass‐loading Zn‐ion hybrid supercapacitors with metal mesh current collectors and aramid nanofiber‐based composite electrolytes, enabling simultaneous load‐bearing capability and enhanced areal energy storage.
Yuseung Choi   +8 more
wiley   +1 more source

Catalytically Enhanced Near Room‐Temperature Hydrogen Sensing Using Pd‐ZnO Colloidal Crystals

open access: yesAdvanced Functional Materials, EarlyView.
Pd‐decorated ZnO colloidal crystal monolayers demonstrate excellent performance across a wide hydrogen concentration range at 33°C, with high selectivity and reproducible device fabrication. The sensors show strong responses even at low‐ppm H2 concentrations and an ultra‐low detection limit of 82 ppb, indicating their suitability for diverse hydrogen ...
Hamidah Alluhaybi   +13 more
wiley   +1 more source

Dopant Distribution in Ga‐Implanted CdO—A Correlative Microscopy and Molecular Dynamics Study

open access: yesAdvanced Functional Materials, EarlyView.
This work demonstrates that ion implantation offset angle could modulate carrier concentration and mobility in cadmium oxide thin films. Combining correlative microscopy workflow and molecular dynamics simulations, this study reveals the control of interfacial cluster density with tailoring implantation angles, and the optimum offset angle that ...
Morvarid Ghorbani   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy