Results 121 to 130 of about 63,098 (305)
Quantum Photothermal Self‐Monitoring Fiber Probes for In Vivo Photothermal Therapy
A miniaturized quantum photothermal fiber probe based on a metal/polymer/glass composite optoelectronic fiber that simultaneously guides lightwave and microwave was developed for the first time. The probe achieves enhanced photothermal conversion (13°C/mW, 25°C–120°C range) while providing real‐time self‐monitoring with 0.2°C thermal resolution at the ...
Wanjun Li +12 more
wiley +1 more source
Multiferroic order parameters – polarization, magnetization, and ferroelastic strain – are positioned as dynamic design variables for batteries. Their mechanistic roles, practical tuning through fabrication and external fields, and ferroic‐resolved characterization routes are unified into a closed‐loop framework, revealing how coupled ferroic responses
Jiaqi Su +13 more
wiley +1 more source
All‐Flex Plasma Patch for In Vivo Delivery of Reactive Species
A fully flexible plasma patch enables stable, conformal treatment on complex biological surfaces and enhances transdermal delivery of reactive species. This platform achieves significant tumor suppression in vivo and reveals coordinated regulation of calcium signaling, metabolism, and programmed cell death, providing a promising strategy for safe and ...
Luxiang Zhao +8 more
wiley +1 more source
Background and Objectives: Acetabular fractures in elderly patients are increasing in incidence and are frequently associated with osteoporotic bone, fracture comminution, marginal impaction, and pre-existing joint degeneration.
Vasileios Athanasiou +1 more
doaj +1 more source
Biodegradable Zn‐Based Implants: Progress, Challenges, and Pathways toward Clinical Translation
Exploring biodegradable Zn‐based implants offers a promising pathway to next‐generation biomedical devices with balanced degradation and biocompatibility. A comprehensive overview of biodegradable Zn‐based implants, covering their biological significance, material design principles, and advanced engineering strategies is provided.
Panfeng Zhao +10 more
wiley +1 more source
Background Hip fractures are most commonly suffered by elderly patients, but 2–11% of hip fractures affect younger patients. In young adults with femoral neck fractures, internal fixation is the recommended treatment for both displaced and non-displaced ...
Michaela Manalili Hansen +6 more
doaj +1 more source
This study utilized alloy micro‐galvanic coupling design to regulate the release of essential elements, thereby programming immune responses and promoting regeneration. The sacrificial anodic process of Zn‐0.8Mg reduced Zn2+ release compared to the “large cathode‐small anode” coupling of Zn‐0.8Fe.
Chaoyang Sun +14 more
wiley +1 more source
Introduction As a novel internal fixation for femoral neck fractures, the femoral neck system has some advantages for young Pauwels type III femoral neck fractures without clear biomechanical effects and mechanisms. Thus, the objection of the study is to
Xiao Fan +5 more
doaj +1 more source

