Results 171 to 180 of about 18,001 (260)
Bio‐Based Polyurethanes for Sustainable and Multifunctional Applications
Bio‐based polyurethanes prepared from vegetable oils, lignin, and polysaccharides have attracted increasing interest as alternatives to fossil‐derived polyurethanes. This review summarizes recent progress in their chemistry, structural engineering, and advanced applications, highlighting the roles of feedstocks, chain‐segment design, dynamic covalent ...
Xin Li +6 more
wiley +1 more source
Microstructure and Mechanical-Tribological Properties of HVOF-Sprayed (WC-Co+Ni) Coatings on Ductile Cast Iron. [PDF]
Ksiazek M, Boron L, Tchorz A.
europepmc +1 more source
Piezo‐Coupling Effects in Smart Polymers: Toward Ultrasensitive Sensing and Biomedical Applications
Piezo‐coupling effects are the foundational factors for the development of multifunctional and self‐powered platforms. Central to this advancement is the use of stimuli‐responsive smart polymers, which offer mechanical flexibility, biocompatibility, and simplified structural complexity with improved sensitivity and energy efficiency.
Duc Khanh Tran +6 more
wiley +1 more source
Local shear mechanical behavior of rock joint under constant normal load. [PDF]
Wang W, Ma H, Dai C, Qian J.
europepmc +1 more source
Given that PEEK chest wall implants induce shear force at the soft tissue‐implant interface due to respiratory motion in the early in vivo post‐implantation stage. We confirmed that this mechanical stimulus triggers the PIEZO1/ITGB1/YAP1 signalling axis in L929 and the STAT6/p‐STAT6 pathway in RAW264.7, which in turn mediates adhesion and migration of ...
Rou Huang +14 more
wiley +1 more source
Scalable Laser Processing Enables Transparent, Accretion Scale-Independent, Ice-Shedding Glass. [PDF]
Wang FW +4 more
europepmc +1 more source
Low N/P cells enable controllable lithium plating, allowing the lithium plating degree (DLi) to be quantified and linked to thermal safety. Pressure signals during calibration provide a non‐destructive route to diagnose DLi, while thermal response tests define safety levels and management strategies. The framework remains applicable in commercial 12 Ah
Haonan Liu +10 more
wiley +1 more source
Comparison of Surface Integrity and Fatigue Performance on TC17 Titanium Alloy After Shot Peening and Re-Shot Peening. [PDF]
Liu C, Ma P, Liu P, Liu D, Guo J.
europepmc +1 more source
A conductive ZrB2 ceramic composite strategy was developed for Mg3(Sb, Bi)2 thermoelectrics to regulate carrier transport and phonon scattering through heterointerface engineering. The 1.0 wt.% ZrB2 composite achieved enhanced room‐temperature performance, with a power factor of 28.51 µW cm−1 K−2 and a peak ZT of 1.22 at 573 K.
Yangyang Xu +7 more
wiley +1 more source
Identification of heat-treated lithic artifacts via quantitative surface gloss characterization. [PDF]
Stárek R, Sahle Y, Atnafu B, Moník M.
europepmc +1 more source

