Results 71 to 80 of about 11,434,288 (193)
Objective Idiopathic intracranial hypertension (IIH) is a neurometabolic disease with an increasing incidence. The pathophysiology is unknown, but improvement of diagnosis and management requires discovery of novel biomarkers. Our objective was to identify such candidate biomarkers in IIH, and secondarily, test for associations between identified ...
Johanne Juhl Korsbæk +10 more
wiley +1 more source
Comparison of frequency doubling technology and standard automated perimetry for detecting glaucomatous visual field progression.
T McCormick (13717474) +7 more
core
Purpose: To evaluate the safety and efficacy of viscocanalostomy in the management of medically uncontrollable primary open-angle glaucoma (POAG) in a developing country.
Khodadad Moradian +4 more
doaj +1 more source
Mechanisms isolated by frequency-doubling technology perimetry.
The frequency-doubling (FD) phenomenon describes the increase in apparent spatial frequency occurring when low-spatial-frequency sine wave gratings undergo rapid counterphase flicker. It is unclear whether the visual mechanisms isolated when pattern appearance is used as a threshold criterion are the same as when a simple detection criterion (as in FD ...
Andrew John, Anderson, Chris A, Johnson
openaire +1 more source
The purpose of this study is to evaluate frequency doubling technology (FDT) perimetry in patients with subtle and moderate visual field (VF) defect from pituitary ...
Mário L. R. Monteiro; Frederico C. Moura; Leonardo P. Cunha
core
Iris claw intraocular lens: A viable option in monocular surgical aphakia
To evaluate the safety and efficacy of iris claw intraocular lens (IOL) implantation for correction of monocular surgical aphakia in eyes with no capsular support. This is a prospective interventional case series of 30 eyes of monocular surgical aphakia.
Raghavendra Rao, Ajita Sasidharan
doaj +1 more source
Variability components of standard automated perimetry and frequency-doubling technology perimetry.
To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma.The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a ...
P G, Spry +3 more
openaire +1 more source
Penetrating orbital injuries from plant material during pond and river diving
Diving into lakes and ponds is a common activity of rural children. We present two cases of penetrating orbital injuries from plant matter sustained in this manner.
Usha R Kim, Kavitha R Sivaraman
doaj +1 more source
Frequency doubling technology perimetry (FDT) was developed as a screening test for glaucoma. It is now used as a general visual screener. Patients with damage to the sensory visual pathways have different patterns of visual loss than glaucoma patients ...
Michael Wall, MD; R. Neahring; K. Woodward
core

