Results 121 to 130 of about 15,073,175 (287)

Electrochemical Behavior of Flame‐Sprayed Sc‐Doped AlCoCrFeMo High‐Entropy Alloy Coatings in 3.5% Sodium Chloride Solution

open access: yesAdvanced Engineering Materials, EarlyView.
Scandium (Sc)‐doped AlCoCrFeMo HEA coatings are fabricated via flame spraying with 0.1, 0.3, and 0.5 wt% Sc additions. Among these, the HEA‐Sc0.3 coating exhibits the highest corrosion resistance, indicated by a more positive corrosion potential and lower current density.
Pankaj Kumar   +7 more
wiley   +1 more source

Levonorgestrel at emergency contraception dose has no effect on ciliary beat frequency and muscular contraction of the human fallopian tube: an in vitro experimental study

open access: yesReproductive Biology and Endocrinology
Background Levonorgestrel (LNG) acts as an emergency contraceptive mainly by inhibiting or postponing ovulation. We carried out this study to investigate whether LNG at concentration relevant for emergency contraception (EC) affect ciliary beat frequency
Raymond Hang Wun Li   +5 more
doaj   +1 more source

Entropy‐Driven Design of Low‐Melting‐Point Alloys via Compositionally Complex Strategy

open access: yesAdvanced Engineering Materials, EarlyView.
Conventional low‐melting‐point alloys (LMPAs) are limited by a narrow compositional space and inherent property trade‐offs. This review presents an entropy‐driven design strategy that overcomes these limitations, ushering in a new class of low‐melting‐point compositionally complex alloys (LMCCAs).
Yinghui Shang   +6 more
wiley   +1 more source

IAEM guidelines for the emergency department assessment of patients with features suspicious for subarachnoid haemorrhage

open access: yes, 2014
These guidelines have been developed in collaboration with the National Neurosurgery Care Programme of the Royal College Of Surgeons in Ireland, by the Academic Committee of the Irish Association for Emergency Medicine, in conjunction with the National ...
Irish Association for Emergency Medicine (IAEM)   +2 more
core  

Investigating the Low‐Temperature Phase Stability of the Binary Ta–W System

open access: yesAdvanced Engineering Materials, EarlyView.
Atomistic simulations show that the binary Ta–W system forms ordered intermetallic phases, B2‐TaW and D03‐TaW3, as 0 K ground states. Configurational entropy, however, lowers the free energy of the disordered bcc solid solution, which becomes the stable phase above about 400 K.
Klemens Lechner   +7 more
wiley   +1 more source

Achieving High ON State Current through Ferroelectric Polarization‐Dependent Interfacial Resistance Switching in Undoped Orthorhombic HfO2 Films

open access: yesAdvanced Functional Materials, EarlyView.
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand   +13 more
wiley   +1 more source

Data-driven Coordinated AC/DC Control Strategy for Frequency Safety [PDF]

open access: yes
With high penetrations of renewable energy and power electronics converters, less predictable operating conditions and strong uncertainties in under-frequency events pose challenges for emergency frequency control (EFC).
Cao, Qianni, Shen, Chen
core  

Advances in Sustainable and Wearable Textile Based Soft Robotics

open access: yesAdvanced Functional Materials, EarlyView.
This Review examines advances in wearable textile‐based soft robotics, focusing on sustainable materials, integrated sensing, and scalable actuation. It discusses manufacturing and system integration across healthcare, assistive robotics, prosthetics, and human–machine interfaces, and highlights key challenges in circular design, including life‐cycle ...
Zahir Abbas   +6 more
wiley   +1 more source

Multimodal Optoelectronic Synapses for Neuromorphic Intelligence: Coupling Light, Electrical, Thermal, and Beyond

open access: yesAdvanced Functional Materials, EarlyView.
This review revisits optoelectronic neuromorphic devices that extend from unimodal sensing toward multimodal perception. Five types of stimuli‐to‐output information flow that are classified based on the device roles within the system and applications are summarized and discussed.
Jihyun Shin   +6 more
wiley   +1 more source

Procedures in emergency medicine: nasopharyngeal airway insertion

open access: yes, 2013
This video is part of a series of videos demonstrating common procedures performed in the Emergency Medicine setting. It was prepared by Cape Town Emergency Medicine's consultants and registrars.
Oosthuizen, Almero   +1 more
core  

Home - About - Disclaimer - Privacy