Results 241 to 250 of about 15,073,175 (287)

Incorporating Demand Response in Two-Stage Frequency Emergency Control

open access: yesInternational Journal of Electrical Power and Energy Systems, 2021
Abstract A decline in power system inertia challenges the frequency control, especially in a regional receiving-end power system. Conventionally, load shedding (LS) is the principal measure to recover the reduction in frequency. This paper proposes a two-stage frequency emergency control (EC) strategy to coordinate the LS and demand response (DR ...
Ping Ju, Yuzhong Gong, Tingyu Jiang
exaly   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

Emerging Frequency Control Mechanisms in IBR Dominated Power Systems

2021 IEEE PES Innovative Smart Grid Technologies - Asia (ISGT Asia), 2021
As inverter-based resource (IBR) penetration increases, system inertia levels are decreasing and the type of frequency response available is changing. This paper explores the adequacy of emerging technologies in providing post-contingency frequency control in the absence of traditional synchronous generators (SGs). The three technologies considered are
Nicholas Maurer   +2 more
openaire   +3 more sources

Emergency control of frequency on the NIE system

Power Engineering Journal, 1988
The authors present the solutions used by NIE (Northern Ireland Electricity) to reconcile the conflicting requirements of overall generation cost minimisation and supply reliability. The performance of the procedures is assessed, and possible improvements presented.
B. Fox, A. McCartney
openaire   +1 more source

Distributional Deep Reinforcement Learning-Based Emergency Frequency Control

IEEE Transactions on Power Systems, 2022
Emergency frequency control is one of the most critical approaches to maintain power system stability after major disturbances. With the increasing number of grid-connected renewable energy sources, existing model-based methods of frequency control are facing up with challenges of computational speed and scalability for large-scale systems.
Jian Xie, Wei Sun
openaire   +1 more source

Frequency Emergency Control Strategy Considering the Operation Speed of Frequency Regulation resources

2018 International Conference on Power System Technology (POWERCON), 2018
In recent years, the power grid is facing more and more frequency stability challenges. In addition to traditional hydro-electric units and thermal power units, the grid requires more kinds of resources to participate in frequency emergency control, such as wind power, high-voltage direct current (HVDC), etc.
Kai Fan   +3 more
openaire   +1 more source

Variable Frequency Control of Induction Motors for Emergency Demand Response

Applied Mechanics and Materials, 2015
The frequency variable drivers of induction motors are typically used to control mechanical load. In the paper a frequency control method is proposed to affect regime of the grid that feeds these motors. The method provides successful self-starting or restarting after significant power disturbance of group induction motors.
Denis Armeev   +2 more
openaire   +1 more source

Aggregation of Electric Vehicles for Emergency Frequency Control of Two-Area Interconnected Grid

2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe), 2020
Frequency control has become more of a concern for the reliable operation of interconnected power systems due to the integration of low inertia renewable to the grid. Electric Vehicle (EV)s have the potential to cooperate in emergency frequency control by a nonlinear control of the power system in case of large disturbances.
Agheb, Sareh   +2 more
openaire   +2 more sources

Study on Frequency Emergency Coordination and Optimal Control with Multitype Measures

2019 IEEE 3rd Conference on Energy Internet and Energy System Integration (EI2), 2019
System moment of inertia and frequency regulation ability is decreasing with the increasing scale of UHVDC and new energy integration in China. Therefore, the frequency stability of the system is becoming increasingly prominent. The cost of traditional security control measures such as generator tripping and load-shedding is high, the low-cost DC ...
Haijun Chang   +8 more
openaire   +1 more source

Study on emergency control based on Regional frequency response model

2011 International Conference on Advanced Power System Automation and Protection, 2011
Frequency stability refers to the ability of a power system to maintain steady frequency following a severe system upset resulting in a significant imbalance between generation and load. The rate of frequency change (df/dt) is an instantaneous indicator of power deficiency and can incipient recognition of power imbalance.
Zhichao Zhang, Zengping Wang, Xin Chen
openaire   +1 more source

Frequency Control in Emergency Conditions

2014
This chapter describes a generalized frequency response model suitable for the analysis of a power system in the presence of significant disturbances and emergency conditions. The effects of emergency control/protection dynamics are properly considered.
openaire   +1 more source

Home - About - Disclaimer - Privacy