Results 261 to 270 of about 272,656 (304)
Some of the next articles are maybe not open access.
FIELD TESTS ON FROST HEAVING CHARACTERISTICS OF GROUND
Doboku Gakkai Ronbunshu, 1991地下水位を1mと0.5mに制御した屋外凍上実験土槽を用いて, 冬期間における凍上量および直径15cmの円板に加わる凍上力の測定を行った. 得られた結果の主なものは次のとおりである. (1) 両土槽の地表面凍上量には明らかな違いが認められ, その違いは主として地表面にごく近い層 (深さ0~5cm) での凍上で現れる. (2) 凍結深さがある程度以上になると発生凍上量は比較的小さくなるが, 円板に加わる凍上力は非常に大きくなる.
Teruyuki SUZUKI +2 more
openaire +1 more source
Thermal characteristics of a hertfordshire frost‐hollow
Quarterly Journal of the Royal Meteorological Society, 1944AbstractRecords of temperature over a 13‐year period in a Hertfordshire valley which has been described as possessing the most “continental” thermal climate yet investigated instrumentally in the British Isles are summarised, discussed, and compared with data from other stations.
openaire +1 more source
Influence of freezing mode on frost heave characteristics
Cold Regions Science and Technology, 1988Abstract Step-freezing and ramped-freezing tests were conducted on samples using a clayey silt passing the 100 sieve with a clay size content of 29% by weight in order to emphasize the influence of various factors such as the rate of cooling, the suction at the frost front and the freezing path.
openaire +1 more source
Frosting characteristics of superhydrophobic surface under desublimation frosting conditions
International Journal of Thermal Sciences, 2023Feng Wang +3 more
openaire +1 more source
The characteristics of frost growth on parallel plates
1999An experimental investigation was undertaken to characterize the effect of environmental conditions on frost growth on a vertical plate in a parallel flow geometry. Humid air was conditioned to have a dew point below 0°C and laminar flow prevailed. The test section was fabricated by using three cooling plates with individual insulators to minimize ...
Heung Do Han, Sung Tack Ro
openaire +1 more source
Frost jacking characteristics of screw piles by model testing
Cold Regions Science and Technology, 2017Abstract The foundations of photovoltaic stents in seasonally frozen regions suffer from uneven frost heave in winter, and the screw piles are widely used to reduce frost diseases. A one-dimensional frost heave model testing was conducted to assess the frost jacking characteristics of several screw piles and a no-helix pile embedded in highly frost ...
Tengfei Wang +3 more
openaire +1 more source
Volume 4: Heat and Mass Transfer Under Extreme Conditions; Environmental Heat Transfer; Computational Heat Transfer; Visualization of Heat Transfer; Heat Transfer Education and Future Directions in Heat Transfer; Nuclear Energy, 2013
The present study aimed to measure and predict frost characteristics and heat transfer rate of fin-tube specimen, and predicted them of fin-tube heat exchanger. Test conditions were air temperature from 0.5 to 7 °C, absolute humidity from 3.18 to 4.01 g/kgDA, air velocity from 0.5 to 2.5m/s, and coolant temperature from −15 to −5 °C.
Jeongkeun Kim, Jieun Hwang, Keumnam Cho
openaire +1 more source
The present study aimed to measure and predict frost characteristics and heat transfer rate of fin-tube specimen, and predicted them of fin-tube heat exchanger. Test conditions were air temperature from 0.5 to 7 °C, absolute humidity from 3.18 to 4.01 g/kgDA, air velocity from 0.5 to 2.5m/s, and coolant temperature from −15 to −5 °C.
Jeongkeun Kim, Jieun Hwang, Keumnam Cho
openaire +1 more source
Review on the measurement and calculation of frost characteristics
International Journal of Heat and Mass Transfer, 2018Abstract As a common physical phenomenon, frost deposition is inevitable and always has significant negative effects on several industry fields, such as aerospace, aviation, and heating, ventilation, air conditioning, and refrigeration. To accurately predict and control a frosting–defrosting cycle, there is a need to understand the interrelated heat,
Mengjie Song, Chaobin Dang
openaire +1 more source
Surface Swelling Characteristics in Concrete under Salt Frost Exposure
Journal of Materials in Civil Engineering, 2020AbstractSalt scaling is a commonly observed durability issue in concrete exposed to a combined salt and frost attack.
Zhichao Liu +3 more
openaire +1 more source
Heat Transfer Engineering, 2013
In this study, frost is grown on microgrooved and flat brass samples under specific operating conditions and a comparison of the condensation, frosting, and defrosting pattern on microgrooved and flat brass surfaces is carried out experimentally. The surfaces are fabricated by a mechanical micromachining process and no chemical alteration of the ...
Md. Ashiqur Rahman, Anthony M. Jacobi
openaire +1 more source
In this study, frost is grown on microgrooved and flat brass samples under specific operating conditions and a comparison of the condensation, frosting, and defrosting pattern on microgrooved and flat brass surfaces is carried out experimentally. The surfaces are fabricated by a mechanical micromachining process and no chemical alteration of the ...
Md. Ashiqur Rahman, Anthony M. Jacobi
openaire +1 more source

