Results 11 to 20 of about 2,779,069 (311)
Testing of a Full-Scale Composite Floor Plate
A full-scale composite floor plate was tested to investigate the flexural behavior and in-plane effects of the floor slab in a grillage of composite beams that reduces the tendency for longitudinal splitting of the concrete slab along the line of the ...
Dennis Lam, Xianghe Dai, Therese Sheehan
doaj +1 more source
Effect of Fouling on the Performance of an Instream Turbine
As the tidal energy industry starts to mature towards commercial projects a key focus is on reliable power performance. As for any marine application, fouling poses a potential performance reduction risk for instream turbine deployments.
Ralf Starzmann +5 more
doaj +1 more source
This work provides insights into the possibility of integrating recovered volatile fatty acids (VFAs) into biological nitrogen removal processes. VFAs are the main products of the acidogenic fermentation of waste sludge and are an effective carbon source
Matteo Grana +2 more
doaj +1 more source
The tests performed on a full-scale prototype of the closure designed for the Pathfinder reactor vessel are described. This head was bolted to another head designed to simulate the reactor vessel. The design pressure of the facility is 700 psig at 500 deg F. Strain gages and brittle coatings were used to determine the stresses in the closure.
Patterson, J. F. +2 more
openaire +2 more sources
In order to study the influence of tension insulator string’s weight on the sags and tensions of ultra-high voltage (UHV) conductors, full-scale testing and theoretical analysis are carried out. The full-scale testing of sags of a three-span transmission
Gang SONG +3 more
doaj +1 more source
Bayesian Model-Updating Implementation in a Five-Story Building
Simplifications and theoretical assumptions are usually incorporated into the numerical modeling of structures. However, these assumptions may reduce the accuracy of the simulation results.
Oscar D. Hurtado +3 more
doaj +1 more source
The BeTOP facility for performance testing of building systems [PDF]
Proposing new materials and systems to improve buildings' performance and energy efficiency often requires testing their performance in the field. Experimental performance characterization of new and existing building systems is crucial to understanding ...
Berardi Umberto
doaj +1 more source
Comparative full-scale fire performance testing of ETICS systems
A full-scale test has been performed to determine fire performance of different ETICS systems (combustible insulation, combustible insulation with fire barrier, non-combustible insulation).
Dubravka Bjegović +4 more
doaj +1 more source
Full-Scale Fire Resistance Testing of Concrete Beams Reinforced with Various FRPR einforcement [PDF]
The widespread use of Fibre-Reinforced Polymers (FRP) reinforced concrete (RC) structural members is hindered by their low fire resistant characteristics, limiting their use to cases, where fire resistance is not a priority.
Kostiantyn Protchenko, Marek Urbański
doaj +1 more source
Dynamic Behaviour of the Arch Bridge - The Full-Scale Testing
In the paper the full-scale dynamic testing procedure for highway bridges is presented. The procedure is applied on the new highway steel arch bridge in highway R1 at the locality Nitra - Selenec.
Milan Moravcik, Martin Moravcik
doaj +1 more source