Results 41 to 50 of about 3,825,971 (175)
Introduction and objectives: Mitral regurgitation is one society’s most prevalent valvular diseases. Transcatheter mitral valve repair with the MitraClip system has become more widely used for the management of this condition.
Alberto Alperi García +10 more
doaj +1 more source
Percutaneous Repair for Secondary Mitral Regurgitation
To the Editor: Obadia et al. (Dec. 13 issue)(1) describe the results of the MITRA-FR trial (Percutaneous Repair with the MitraClip Device for Severe Functional/Secondary Mitral Regurgitation), a randomized, controlled trial of this device for ...
Munafò, Andrea +2 more
core +1 more source
A unifying device–cardiovascular interface framework is presented to classify implantable cardiovascular technologies as intracardiovascular blood‐contacting systems or extracardiovascular tissue‐only and blood‐handling architectures. Cross‐class comparison across shared semiquantitative criteria, including blood‐contact burden, biomimicry ...
Bergo Nicolò +7 more
wiley +1 more source
ABSTRACT The case regards a 73‐year‐old male who was referred for consideration of percutaneous left atrial appendage closure. His left atrial appendage was ligated during prior mitral valve surgery, but was noted to be patent on a recent transesophageal echocardiography. An Amulet device was selected based on CT planning.
Zach Rozenbaum, Eric Gnall
wiley +1 more source
Demographic and Clinical Features in Patients with Mitral Insufficiency of Ischemic Genesis
Myocardial infarction is often associated with ischemic mitral regurgitation. In most patients, ischemic mitral regurgitation develops gradually due to remodeling of the ischemic myocardium and changes in hemodynamics in the left ventricle.
S. A. Rudenko +2 more
doaj +1 more source
MitraClip for Secondary Mitral Regurgitation
We describe the case of an 83-year-old man with a history of ischemic cardiomyopathy and severe secondary mitral regurgitation. This case highlights the role of transcatheter edge-to-edge repair with the MitraClip in the management of symptomatic ...
Brian D. McCauley, MD, MPH +3 more
doaj +1 more source
ABSTRACT The SAPIEN M3 system has been recently approved for transcatheter mitral valve replacement (TMVR). The transeptal guide sheath is used to deploy the dock, which is completely released before inserting and deploying the M3 valve using the same femoral access, transeptal puncture (TSP) and guide sheath.
Clara Fernandez‐Cordon +5 more
wiley +1 more source
Functional and ischemic mitral regurgitation
Unlike organic mitral regurgitation, so-called “functional” or “secondary” mitral regurgitation (MR) is related to progressive left ventricular dilatation, remodeling, dyssinchrony or distortion involving the mitral apparatus.
A. Di Mauro +6 more
core +2 more sources
Functional, Ischemic Mitral Regurgitation [PDF]
With an ever increasing population of patients with coronary artery disease complicated by chronic ischemic mitral regurgitation (IMR), the question of whether to perform mitral valve repair (MVRep) in addition to coronary artery bypass grafting (CABG) is one of the most common and controversial clinical dilemmas faced by cardiac surgeons today.
Michael H, Kwon +2 more
openaire +2 more sources
Abstract Wild‐type transthyretin amyloid cardiomyopathy (ATTRwt‐CM) is a progressive and infiltrative cardiac disorder that may cause fatal consequences if left untreated. The estimated survival time from diagnosis is approximately 3–6 years. Because of the non‐specificity of initial symptom manifestation and insufficient awareness among treating ...
Yasuhiro Izumiya +9 more
wiley +1 more source