Results 121 to 130 of about 11,766 (167)
Some of the next articles are maybe not open access.
Powder Technology, 2012
Abstract Quality of fluidization is an important criterion for efficient heat and mass transfer in gas–solid fluidized beds. Knowledge of voidage distribution in fluidized bed is essential when exothermic reactions are carried out in fluidized beds.
MANDAL, D +4 more
openaire +2 more sources
Abstract Quality of fluidization is an important criterion for efficient heat and mass transfer in gas–solid fluidized beds. Knowledge of voidage distribution in fluidized bed is essential when exothermic reactions are carried out in fluidized beds.
MANDAL, D +4 more
openaire +2 more sources
Micron, 2010
Precipitates of the ordered L1(2) gamma' phase (dispersed in the face-centered cubic or FCC gamma matrix) were imaged in Rene 88 DT, a commercial multicomponent Ni-based superalloy, using energy-filtered transmission electron microscopy (EFTEM). Imaging was performed using the Cr, Co, Ni, Ti and Al elemental L-absorption edges in the energy loss ...
J S, Tiley +6 more
openaire +2 more sources
Precipitates of the ordered L1(2) gamma' phase (dispersed in the face-centered cubic or FCC gamma matrix) were imaged in Rene 88 DT, a commercial multicomponent Ni-based superalloy, using energy-filtered transmission electron microscopy (EFTEM). Imaging was performed using the Cr, Co, Ni, Ti and Al elemental L-absorption edges in the energy loss ...
J S, Tiley +6 more
openaire +2 more sources
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
Abstract Void fraction simulating stratified air–water flow in cylindrical tubes of different radii was measured using transmission and scattering of gamma rays. A simple experimental set-up using 137 Cs γ-ray point source of 10 μCi and NaI(Tl) detector was used.
openaire +1 more source
Abstract Void fraction simulating stratified air–water flow in cylindrical tubes of different radii was measured using transmission and scattering of gamma rays. A simple experimental set-up using 137 Cs γ-ray point source of 10 μCi and NaI(Tl) detector was used.
openaire +1 more source
A kilonova following a long-duration gamma-ray burst at 350 Mpc
Nature, 2022Jillian Rastinejad +2 more
exaly
Gamma-ray transmission technique for quality control of coal seams
Fuel and Energy Abstracts, 2003openaire +1 more source
Dual-Hop FSO Transmission Systems Over Gamma–Gamma Turbulence With Pointing Errors
IEEE Transactions on Wireless Communications, 2017Emna Zedini +2 more
semanticscholar +1 more source

