Results 51 to 60 of about 64,212 (257)
Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets [PDF]
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm thickness carbon targets have been studied with high-resolution silicon microstrip detectors of the UA9 apparatus at the H8 line at CERN.
Abbiendi, G. +24 more
core +2 more sources
Comparison between GEANT4 and MCNP for well logging applications [PDF]
MCNP and GEANT4 are two reference Monte Carlo nuclear simulators, MCNP being the standard in the Oil & Gas nuclear logging industry. While performing a simulation benchmark of these two software for the purpose of “Cased Hole” wellbore evaluation ...
Varignier Geoffrey +8 more
doaj +1 more source
Experimental spectra analysis in THM with the help of simulation based on Geant4 framework [PDF]
The Coulomb barrier and electron screening cause difficulties in directly measuring nuclear reaction cross sections of charged particles in astrophysical energies.
Fu, Yuanyong +7 more
core +2 more sources
A single-event effect (SEE) simulation toolkit has been developed at CERN for the whole radiation effects community and released as an open-source code. It has been validated by comparing the simulated energy deposition of inelastic interactions, due to ...
D. Lucsányi +5 more
semanticscholar +1 more source
Calculation of spectrum and neutron flux density in experimental channels of WWR-M reactor
A program for calculating the spectra and densities of neutron fluxes in the experimental channels of the research reactor WWR-M was developed. To do this, the reactor core was modeled. Irradiation of neutron activation detectors was performed.
O. G. Diakov +4 more
doaj +1 more source
Quantitative Test of the Evolution of Geant4 Electron Backscattering Simulation
Evolutions of Geant4 code have affected the simulation of electron backscattering with respect to previously published results. Their effects are quantified by analyzing the compatibility of the simulated electron backscattering fraction with a large ...
Basaglia, Tullio +6 more
core +1 more source
Measurement of out of field doses in brain proton therapy with GATE simulations
Proton therapy as one of the radiotherapy applications, aims to treat the tumor by using the accelerated proton particle. High radiation dose distributions delivered to the tumor tissue, is characterized with Bragg curves, while the radiation in the ...
Melisa Sönmez, Sinan Kuday
doaj +1 more source
Extending Geant4 Parallelism with External Libraries (MPI, TBB) and Its Use on HPC Resources
With Geant4 Version 10.0, released in December 2013, one of the most widely used Monte-Carlo codes has been ported to take full advantage of multi- and many-core CPUs thanks to the introduction of event-level parallelism via multithreading. In this paper
Asai, Makoto +4 more
core +3 more sources
In this study, mass attenuationcoefficients (µm), transmission fractions (T), mean free path (MFP) and halfvalue layer (HVL) of the (90-x)TeO2—xMoO3—10ZnOglass system (x=10, 20 and 30 mol%) were calculated at the gamma rayphoton energies of 356 keV, 662 ...
Ali Aşkın, Murat Dal
doaj +1 more source
Direct measurement of neutrons induced in lead by cosmic muons at a shallow underground site
Neutron production in lead by cosmic muons has been studied with a Gadolinium doped liquid scintillator detector. The detector was installed next to the Muon-Induced Neutron Indirect Detection EXperiment (MINIDEX), permanently located in the T\"ubingen ...
Abt, Iris +11 more
core +1 more source

