Results 281 to 290 of about 16,587,431 (369)

Measurement of CT radiation beam width with a pencil ionization chamber and radiopaque mask

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study compares fan beam CT scanner radiation beam widths measured with a pencil ionization chamber‐radiopaque mask technique with commonly used film and computed radiography (CR) measurements. Methods For a given fan beam CT scanner x‐ray beam, the ionization chamber‐mask technique determines the radiation beam width by exposing a
Rani Al‐Senan   +2 more
wiley   +1 more source

Modelling of a double‐scattering proton therapy nozzle using the FLUKA Monte Carlo code and analysis of linear energy transfer in patients treated for prostate cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The dose‐averaged linear energy transfer (LETD) in proton therapy (PT) has in pre‐clinical studies been linked to the relative biological effectiveness (RBE) of protons. Until recently, the most common PT delivery method in prostate cancer has been double‐scattered PT, with LETD only available through dedicated Monte Carlo (MC ...
Rasmus Klitgaard   +7 more
wiley   +1 more source

Correction: The sarcoma ring trial: a case-based analysis of inter-center agreement across 21 German-speaking sarcoma centers. [PDF]

open access: yesJ Cancer Res Clin Oncol
Roohani S   +60 more
europepmc   +1 more source

A review of artificial intelligence in brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen   +4 more
wiley   +1 more source

The long-term general practice healthcare of women with a history of gestational diabetes: A Scoping Review Protocol. [PDF]

open access: yesHRB Open Res
O'Flynn J   +6 more
europepmc   +1 more source

A Generalization of the Least General Generalization

open access: yesA Generalization of the Least General Generalization
In this paper, we describe a polynomial time algorithm, called a k-minimal multiple generalization (k-mmg) algorithm, where $ k gep 1$, and its application to inductive learning problems. The algorithm is a natural extension of the least general generalization algorithm developed by Plotkin.
openaire  

Improving organ dose sparing in left‐sided breast cancer with yaw‐limited volumetric modulated arc therapy: A dosimetric comparison to conventional and intensity modulated radiation therapy approaches

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background To assess the dose‐sparing capabilities of a yaw‐limited volumetric modulated arc therapy (YL_VMAT) beam setup for adjacent organs at risk (OAR) in comparison with 3D‐conventional radiation therapy (3D‐CRT), intensity‐modulated radiation therapy (IMRT) and conventional VMAT for radiation therapy in left‐sided breast cancer patients.
Gerhard Pollul   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy