Results 161 to 170 of about 2,988,281 (363)

Investigation of the Uniformity of Gel Shrinkage by Imaging Tracer Particles Using X‐Ray Microtomography

open access: yesAdvanced Engineering Materials, EarlyView., 2023
A novel method for tracking structural changes in gels using widely accessible microcomputed tomography is presented and validated for various hydro‐, alco‐, and aerogels. The core idea of the method is to track positions of micrometer‐sized tracer particles entrapped in the gel and relate them to the density of the gel network.
Anja Hajnal   +3 more
wiley   +1 more source

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki   +9 more
wiley   +1 more source

A comparative analysis of deep learning architectures with data augmentation and multichannel input for locoregional breast cancer radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Studies on deep learning dose prediction increasingly focus on 3D models with multiple input channels and data augmentation, which increases the training time and thus also the environmental burden and hampers the ease of re‐training. Here we compare 2D and 3D U‐Net models with clinical accepted plans to evaluate the appropriateness of
Rosalie Klarenberg   +2 more
wiley   +1 more source

Assessing the rigidity of thermoplastic masks for head immobilization effectiveness in stereotactic radiosurgery

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study compared three Brainlab thermoplastic masks—Cranial 4pi basic, stereotactic (Close Mask V2), and open‐face—to see how well they limited head movement during Stereotactic Radiosurgery (SRS). Using a head phantom, we tested rotational movements (pitch, yaw, and roll) and measured displacements with the ExacTrac system.
Iris Pasion Apale   +2 more
wiley   +1 more source

Characterization of a prototype rapid kilovoltage x‐ray image guidance system designed for a linear accelerator radiation therapy unit

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates a novel cone‐beam computed tomography (CBCT) imaging solution integrated onto a conventional C‐arm linear accelerator (linac) with increased gantry speed. The purpose is to assess the impact of improved imaging hardware and reconstruction algorithms on image quality.
Theodore Arsenault   +9 more
wiley   +1 more source

The Geometry of Relations

open access: yesOrder, 2010
There is a canonical way to associate two simplicial complexes K, L to any relation $R\subset X\times Y$. Moreover, the geometric realizations of K and L are homotopy equivalent. This was studied in the fifties by C.H. Dowker. In this article we prove a Galois-type correspondence for relations $R\subset X\times Y$ when X is fixed and use these ...
openaire   +4 more sources

Monte Carlo modeling of radiation dose from radiation therapy with superficial x‐rays

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction Superficial x‐rays (50–100 kVp) are used for treating non‐melanoma skin cancer and intraoperative radiation therapy (IORT). At these energies, the photoelectric effect significantly increases absorbed dose to bone compared to soft tissue.
Reham Barghash   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy