Results 211 to 220 of about 430,041 (297)

The tele-gesture: problems of networked gesture

open access: yes, 2001
This paper focuses on the problems of networked gestures. The tele-gesture is the achievement of a remote gesture. To reach a good sensory perception of the distant scene, it is necessary to create a specific flow for the haptic data: position, orientations, and feedback forces. This flow presents intrinsically a bi-directional characteristic.
Guerraz, Agnès   +3 more
openaire   +3 more sources

From 2D to 3D gamma passing rate tolerance and action limits for patient‐specific quality assurance in volumetric‐modulated arc therapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Volumetric modulated arc therapy (VMAT) requires an accurate patient‐specific quality assurance (PSQA) program. In clinical practice, this is usually performed using the γ‐index and the two‐dimensional gamma passing rate (2D %GP). A three‐dimensional (3D) index incorporating the patient anatomy could be more useful for the 3D dose ...
Christos Zarros   +6 more
wiley   +1 more source

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source

Evaluating the use of diagnostic CT with flattening filter free beams for palliative radiotherapy: Dosimetric impact of scanner calibration variability

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut   +2 more
wiley   +1 more source

Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka   +6 more
wiley   +1 more source

JACMP – Founding and 2000–2004

open access: yes
Journal of Applied Clinical Medical Physics, EarlyView.
Michael Mills
wiley   +1 more source

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy