Results 231 to 240 of about 430,041 (297)

Dosimetric effect of silicone‐based gel on skin surface during volumetric modulated arc therapy for breast cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to quantify and compare the dosimetric effects of varying thicknesses of StrataXRT, a silicone‐based gel, and other topical agents on the skin surface during volumetric modulated arc therapy (VMAT) for breast cancer.
Tenyoh Suzuki   +13 more
wiley   +1 more source

Quantification and dosimetric impact of intra‐fractional bladder changes during CBCT‐guided online adaptive radiotherapy for pelvic cancer treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study quantitatively evaluates bladder changes and their dosimetric impact during the on‐couch adaptive process on a commercial CBCT‐based online adaptive radiotherapy (CT‐gART) platform. Methods Data from 183 fractions of ten patients receiving online ART for pelvic cancers were analyzed retrospectively.
Ingrid Valencia Lozano   +7 more
wiley   +1 more source

Diagnostic image‐based treatment planning for online adaptive ultra‐hypofractionated prostate cancer radiotherapy with MR‐Linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose A new workflow was investigated for Elekta Unity MR‐Linac by removing the computed tomography (CT)‐simulation step and using diagnostic CT (DCT) for reference plan generation. Materials and methods Ten patients with ultra‐hypofractionated prostate cancer treated with magnetic resonance imaging (MRI)‐guided adaptive radiotherapy were ...
Yuan Xu   +5 more
wiley   +1 more source

Position‐dependent offset corrections for ring applicator reconstruction in cervical cancer brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi   +3 more
wiley   +1 more source

Evaluation of dosimetric and spatial accuracy of a virtual cone technique for radiosurgery using linac‐integrated CBCT‐based polymer gel dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy