Results 191 to 200 of about 31,757 (253)
Experimental Study on Flexural Performance of SFCB-Reinforced ECC-Concrete Composite Beams. [PDF]
Ling Y +5 more
europepmc +1 more source
Dynamics of Drone Blades Based on Polymer Nanocomposites Incorporating Graphene, Carbon Nanotube, and Fullerene. [PDF]
Gomera WG, Tański T, Kim JY.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Degradation of glass fiber reinforced polymer (GFRP) bars in concrete environment
Construction and Building Materials, 2021Abstract Degradation of tensile, shear and flexure properties of glass fiber reinforced polymer (GFRP) bars is investigated in the paper. Glass fibre reinforced polymer bars, when used in structures exposed to aggressive environments, can significantly increase the lifetime, as compared to structures reinforced with conventional steel.
Paulina Arczewska +2 more
openaire +2 more sources
Flexural Behavior of Concrete Beams Reinforced with Glass Fiber-Reinforced Polymer (GFRP) Bars
ACI Structural Journal, 2000Concrete members reinforced with glass fiber-reinforced polymer (GFRP) bars exhibit large deflections and crack widths compared with concrete members reinforced with steel. This is due to the low modulus of elasticity of GFRP. Current design methods for predicting deflections at service load and crack widths developed for concrete structures reinforced
H. Toutanji, M. Saafi
openaire +2 more sources
Composite Structures, 2021
Abstract A combination of fiber-reinforced polymer (FRP) reinforcing bars and steel fibers can be employed in locations of a structure with reinforcement congestion instead of the conventional combination of steel rebars and stirrups. In this study, first, the shear performance of the FRP bar-reinforced concrete beams containing steel fibers and ...
Seyyed-Asgar Hosseini +2 more
openaire +2 more sources
Abstract A combination of fiber-reinforced polymer (FRP) reinforcing bars and steel fibers can be employed in locations of a structure with reinforcement congestion instead of the conventional combination of steel rebars and stirrups. In this study, first, the shear performance of the FRP bar-reinforced concrete beams containing steel fibers and ...
Seyyed-Asgar Hosseini +2 more
openaire +2 more sources
ACI Materials Journal, 2002
Broad applications of fiber-reinforced polymer reinforcement are hindered by its elastic brittle behavior, resulting in reduced structural ductility. In addition, due to the lower modulus of elasticity, serviceability considerations such as deflection and crack width control present serious challenges to designers.
V. Li, Shuxin Wang
openaire +2 more sources
Broad applications of fiber-reinforced polymer reinforcement are hindered by its elastic brittle behavior, resulting in reduced structural ductility. In addition, due to the lower modulus of elasticity, serviceability considerations such as deflection and crack width control present serious challenges to designers.
V. Li, Shuxin Wang
openaire +2 more sources
Design and Analysis of Glass Fiber Reinforced Polymer (GFRP) Leaf Spring
2011 Fourth International Conference on Emerging Trends in Engineering & Technology, 2011Weight reduction is now the main issue in automobile industries. Weight reduction can be achieved primarily by the introduction of better material, design optimization and better manufacturing processes. The achievement of weight reduction with adequate improvement of mechanical properties has made composite a very good replacement material for ...
B.B. Deshmukh, S.B. Jaju
openaire +2 more sources
Canadian Journal of Civil Engineering, 2004
Tension stiffening and cracking of axial tension members is evaluated for concrete reinforced with steel (reinforcing ratio ρ = 2.0%) and glass fiber reinforced polymer (GFRP) bars (1.3%, 2.0%, and 2.9%), with shrinkage included in the analysis of the member response.
Peter H Bischoff, Richard Paixao
openaire +2 more sources
Tension stiffening and cracking of axial tension members is evaluated for concrete reinforced with steel (reinforcing ratio ρ = 2.0%) and glass fiber reinforced polymer (GFRP) bars (1.3%, 2.0%, and 2.9%), with shrinkage included in the analysis of the member response.
Peter H Bischoff, Richard Paixao
openaire +2 more sources

