Results 71 to 80 of about 28,117 (245)

Toward Wireless Implantable Robotic Systems Driven by Magnetic Field for Personalized Therapy

open access: yesAdvanced Robotics Research, EarlyView.
Robotic materials are playing an increasingly vital role in enabling sensing and actuation at small scales. This perspective highlights recent advances in magnetic materials and magnetically actuated devices for wireless sensing, actuation, and energy harvesting toward implantable robotic systems for closed‐loop therapy.
Yusheng Wang, Ruijian Ge, Xiaoguang Dong
wiley   +1 more source

A Comparison of Clinical Outcomes After XEN Gel Stent and EX-PRESS Glaucoma Drainage Device Implantation

open access: yesJournal of glaucoma, 2021
Supplemental Digital Content is available in the text. Precis: Although the XEN stent offers a lower risk of hypotony and choroidal effusions with fewer clinic visits postoperatively, its surgical success rate was inferior to the EX-PRESS shunt. Purpose:
Ari M. Stoner   +6 more
semanticscholar   +1 more source

Cracking pressure control of parylene checkvalve using slanted tensile tethers [PDF]

open access: yes, 2010
MEMS check valves with fixed cracking pressures are important in micro-fluidic applications where the pressure, flow directions and flow rates all need to be carefully controlled.
Lin, Jeffrey Chun-Hui   +2 more
core   +1 more source

Vitreoretinal complications and surgical outcomes in patients with X‐linked retinoschisis

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose X‐linked retinoschisis (XLRS) is an inherited vitreoretinal disorder characterized by macular retinoschisis. In a subgroup of patients, peripheral retinoschisis can occur, potentially leading to complications such as vitreous haemorrhage (VH) and retinal detachment (RD).
Jonathan Hensman   +11 more
wiley   +1 more source

Incidence and outcomes of hypertensive phase after glaucoma drainage device surgery.

open access: yesOphthalmology Glaucoma
PURPOSE To describe the incidence, risk factors, clinical characteristics, and long-term outcomes of a hypertensive phase (HP) after glaucoma drainage device (GDD) implantation.
Minjia Tang, N. Gill, A. Tanna
semanticscholar   +1 more source

Need for Additional Glaucoma Surgery and Complications Following Glaucoma Drainage Device Surgery

open access: yesJournal of glaucoma, 2021
Supplemental Digital Content is available in the text. Précis: In this longitudinal study of patients with open-angle (OAG), pseudoexfoliative (PXE), or neovascular glaucoma (NVG) receiving glaucoma drainage devices (GDD), posttube cumulative rates of ...
Felix F. Kung   +8 more
semanticscholar   +1 more source

Safety and efficacy of Ahmed glaucoma valve implantation in refractory glaucomas in Northern Indian eyes [PDF]

open access: yes, 2014
PurposeTo evaluate the safety and efficacy of Ahmed glaucoma valve (AGV) implantation in refractory glaucoma in Northern Indian eyes.BackgroundThe success rate of trabeculectomy remains low in cases of refractory glaucoma even with the use of ...
Agrawal, Anugya   +4 more
core   +1 more source

Randomized, single‐centre, double‐blinded repeated dose investigation of safety and tolerability of ocular administrations of a novel silica eye drop product in healthy volunteers

open access: yesActa Ophthalmologica, EarlyView.
Abstract Purpose Managing ocular diseases often requires frequent eye drop administration, which can challenge patient compliance. A long‐acting eye drop technology using an amorphous synthetic silica composite was developed to address this. Our study aimed to assess the safety and tolerability of the Silica Eye Drop platform in healthy volunteers over
Aleksandra Poluianova   +5 more
wiley   +1 more source

Risk factors for exposure of Baerveldt glaucoma drainage implants: a case-control study

open access: yesBMC Ophthalmology, 2020
Background Glaucoma drainage implant exposure is one of the serious complications after glaucoma drainage implant surgery. The purpose of this study is to evaluate the risk factors for exposure of the device after implantation of a Baerveldt glaucoma ...
Ayaka Edo, Koji Jian, Yoshiaki Kiuchi
doaj   +1 more source

Intracameral vent and flush technique for silicone oil blockade in Ahmed glaucoma valve

open access: yesIndian Journal of Ophthalmology, 2022
The presence of emulsified silicone oil in the eye can lead to many complications, glaucoma being one of the most common. Adequate IOP control is difficult to achieve with medical management alone; surgical intervention is often required.
Vaibhav Namdev   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy